Overview and designation of coils, order numbers
Coils with DC power supply, cable grommet, without cable
Designation on the coil
EX18 046 10W 12V DC
EX18 046 10W 24V DC
EX18 046 10W 48V DC
EX18 046 10W 110V DC
Coils with 50/60 Hz AC power supply and attached cable (3 / 8 m)
Designation on the coil
EX18 046 10W 110V AC 3M
EX18 046 10W 110V AC 8M
EX18 046 10W 230V AC 3M
EX18 046 10W 230V AC 8M
Coils for explosive atmospheres - ARGO-HYTOS ordering code
Solenoid coil
for explosive atmospheres
internal diameter 22 mm
Casing
DC power supply
Terminal + cable grommet
AC power supply 50/60 Hz
Installed cable
Valve hydraulic part seal kit
Valve type
Position
Set order number
1
O-ring 23.47 x 2.95 NBR
2
Dualseal 19.62 x 22.22 x 3.8 PU
The storage conditions for seals are specified in ISO 2230 - Rubber products - Storage guidelines:
Seals to be stored:
› in covered, dry and tempered areas at temperatures of +15 to +25 °C, away from direct heat sources
› protected from the weather, direct sunlight and ultraviolet radiation
› undeformed, on a clean flat base in the original packaging
› out of reach of petroleum and chemical substances
Rubber group
Chemical name abbreviation according to ISO
A
Polyurethane AU
B
NBR
C
FKM / FPM (Viton)
C
VMQ

7.9 Product disposal

Remove the valve from the hydraulic circuit (see chapter 7.6.1 Emergency and emergency situations). Remove as much residual
working fluid from the valve as possible.Dispose of the valve in an environmentally friendly manner in accordance with the
applicable regulations. The valve is mainly made of recyclable materials such as low carbon steel, copper wire, etc.
(see chapter 4.2 Materials used).

8. Manufacturer contact

ARGO-HYTOS s.r.o.
Dělnická 1306 • CZ - 543 01 VRCHLABÍ • Czech Republic
Tel. +420 499 403 111 • E-mail:
www.argo-hytos.com
Instructions_SD3EX-C2*S5(S6)_14091_1en_01/2023
P
[W]
U
[V DC]
N
N
10
12
10
24
10
48
10
110
P
[W]
U
[V AC]
N
N
10
110
10
110
10
230
10
230
EX22 - 46 /
12 V DC
01200
24 V DC
02400
48 V DC
04800
110 V DC
11000
110 V AC
11050
230 V AC
23050
SD3EX-C2*S5(S6)
40730500
1
pcs
1
info.cz@argo-hytos.com
Designation ARGO-HYTOS
EX22-46/01200-10W-B
EX22-46/02400-10W-B
EX22-46/04800-10W-B
EX22-46/11000-10W-B
Designation ARGO-HYTOS
EX22-46/11050-10W3M-B
EX22-46/11050-10W8M-B
EX22-46/23050-10W3M-B
EX22-46/23050-10W8M-B
- 10
- B
520 h in NSS according to ISO 9227
without designation
3M
8M
2
Polyester urethane rubber
Butadiene acrylonitrile rubber
Fluoroelastomer
Vinyl-methyl - silicone rubber
Order number
42141000
42140900
42140600
42140100
Order number
42139600
42139800
42140700
42140800
Casing surface protection
Cable length
without cable
cabel 3 m
cabel 8 m
Nominal coil input power
10 W
1
Length of storage
5 years
7 years
10 years
10 years