Valve Characteristics; Legislation And Standards; Product Modifications; Ordering Code - Argo-Hytos SD3EX-B2 Gebrauchsanweisung

2/2 elektromagnetisch betätigte hydraulische einbau-sitzventile, indirekt gesteuert, ausgelegt für den betrieb in explosionsgefährdeten bereichen
Vorschau ausblenden Andere Handbücher für SD3EX-B2:
Inhaltsverzeichnis

Werbung

4.6 Valve characteristics

Characteristics measured at = 32 mm
Valve SD3EX-C2*S5(S6)
Operating limits (p-Q)
Teplota okolí 70 °C (158 °F), napětí U
(5076)
350
(4351)
300
(3626)
250
(2901)
200
(2176)
150
(1450)
100
(725)
50
0
25
50
(6.6)
(13.2)
Flow Q [l/min (GPM)]
Connected
1
2S5
1
2S6

4.7 Legislation and standards

The valve complies with the relevant requirements of legislation and standards as amended:
ČSN EN ISO 4413
Hydraulics - General rules and safety requirements for hydraulic systems and their components
Other regulations and standards used:
ČSN ISO 6403
Hydrostatic drives. Valves for flow and pressure control. Test methods
ČSN ISO 4411
Measurement of the characteristics Δp = function (Q) of hydraulic valves
ČSN EN ISO 9001
Quality management systems
ČSN EN ISO 12100
Machine safety / risk analysis
Directive 2006/42/EU on machinery / used chapters: 1.7.4 Instructions for use, Annex III CE marking
ČSN EN 82079-1
Preparation of instruction manuals - Structure, content and presentation / Part 1: General principles and detailed requirements
5. Product modification
An overview of possible valve modifications is described in the ordering code.
The number of spool positions, the spool connection and the type of emergency control and the electrical parameters of the coil cannot be
subsequently changed by the user.In the case of a valve with a 10 W coil, the coil surface temperature and the application for the temperature class
can be affected by adjusting the ambient temperature (see 4.4 Ambient temperature range for each class).
The coils with AC power supply and built-in rectifier are supplied with only the cable attached, with optional lengths of 3 and 8 m as standard.

Ordering Code

Explosion proof 2/2 directional valve,
solenoid operated, poppet type,
piloted
Valve cavity
1-1/16-12UN / C2 (VC12-2)
Model
High performance
Model / Symbol
normally closed (NC),
blocking
normally open (NO),
blocking
DC voltage connection box + cable gland
12 V DC / 0.75 A
24 V DC / 0.39 A
48 V DC / 0.19 A
110 V DC / 0.094 A
AC voltage 50/60 Hz, fix installed cable
110 V AC / 0.112 A
230 V AC / 0.052 A
www.argo-hytos.com
Instructions_SD3EX-C2*S5(S6)_14091_1en_01/2023
/s (156 SUS)
2
-10 % (24 V DC), výkon P
N
75
100
125
150
(19.8)
(26.4)
(33.0)
(39.6)
Direction
1→2, 2→1
1→2, 2→1
SD3EX - C2 / H
/
2S5
2S6
01200
02400
04800
11000
11050
23050
Pressure drop as a function of flow rate (∆p-Q)
10 W
N
1
1
- B
No designation
No designation
M7
M9
No designation
3
8
A4
A6
*EAEU= Eurasian Economic Union, certificate according to TR TS 012/2011 valid
for the Russian Federation, Belarus, Armenia, Kazakhstan and Kyrgyzstan.
Flow Q [l/min (GPM)]
Connected
Direction
Solenoid
2S5
1→2, 2→1
ON
2S6
1→2, 2→1
OFF
Certifications of valve
No designation
A
E
EAC for Russian federation
zinc-coated (ZnNi), ISO 9227 (520 h)
standard for 2S6 only
detent assembly for 2S6 only
without manual override
(only for DC)
(AC and DC version)
(AC and DC version)
Temperature class - solenoid nominal power
ATEX, IECEx
IECEx for Australia
Surface treatment
Seals
NBR
Manual override
Cable length
without cable
3000 mm
8000 mm
class T4 - 10 W
class T6 (T5) - 10 W
Page 11