Herunterladen Inhalt Inhalt Diese Seite drucken

Materials Used; Surface Protection Against Corrosion; Basic Technical Parameters; Working Fluid - Argo-Hytos SD3EX-B2 Gebrauchsanweisung

2/2 elektromagnetisch betätigte hydraulische einbau-sitzventile, indirekt gesteuert, ausgelegt für den betrieb in explosionsgefährdeten bereichen
Vorschau ausblenden Andere Handbücher für SD3EX-B2:
Inhaltsverzeichnis

Werbung

4.2 Materials used

Cone - hardened steel
Non-magnetic ring and control pin - Cr-Ni stainless steel (8% to 10% Ni)
Control system stopper - brass
Compression spring - patented steel spring wire
Other parts of the hydraulic part of the valve, solenoid control system, spool casing and cap, spool clamping nut - steel
Valve seals - NBR, Polyurethane (Dualseal)
Coil body - PA
Coil winding - enamelled copper wire
Coil seal - silicone rubber
The materials used are not included in the lists of prohibited and mandatory documented substances Directive 2015/863/EU (RoHS) and EU
Regulation 1907/2006 (REACH).

4.3 Surface protection against corrosion

The valve surface is galvanized with 520 h corrosion protection in NSS according to ISO 9227. Surface layer without hexavalent chronium Cr+6.

4.4 Basic technical parameters

Parameter
Valve connection thread
Maximum pressure
Maximum flow
Pressure losses as a function of flow rate
Fluid temperature
Max. switching frequency
Working fluid kinematic viscosity range
Minimum required working fluid purity
Lifetime
Weight of valve with solenoid
Technical data of the solenoid with certification for explosive environments
Voltage type
Nominal supply voltage (U
)
N
Supply voltage fluctuations
Supply coil input power
Duty cycle
Electrical protection IP according to EN 60529
Ambient temperature range for each surface temperature class T4, T5, T6
Temperature class
Nominal coil input power
T4 – 135 °C
T5 – 100 °C
10 W
T6 – 85 °C
*IP68 – test conditions: product submerged 1m under water for 1 hour.

4.5 Working fluid

The valve is designed for common hydraulic working fluids:
› mineral oils of performance classes HM and HV according to ISO 6734-4
› non-flammable and difficult to ignite hydraulic fluids according to ISO 12922
› environmentally acceptable hydraulic fluids according to ISO 15380
NOTICE:
NBR seal material is not suitable for some working fluid groups, such as the HFD group.
In case of uncertainty, we recommend to perform a test of the mutual tolerance of the seal material and the working fluid.
Page 10
Unit
bar (PSI)
l/min (GPM)
bar (PSI)
°C
1/h
mm
s
2
-1
class
cycles
kg (lbs)
AC 50 / 60 Hz
V
110, 230
W
Ambient temperature range
°C
Value
1-1/16-12 UN / C2 (VC12-2)
350 (5076)
150 (39.6)
graph ∆p = f (Q)
-30 ... +70
7 000
10 to 400
19/16/13 ISO 4406
10
7
1.70 (3.75)
DC
12, 24, 48, 110
± 10 % U
N
10
100 % ED
IP66 / IP68*
-30 ... +70
-30 ... +55
-30 ... +45
www.argo-hytos.com