Herunterladen Inhalt Inhalt Diese Seite drucken

Continuous Drainage; Long-Term Storage - Toyotomi TAD-2220E Bedienungsanleitung

Lokale klimageräte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
ously for 1 second, WiFi module will restore to
factory default setting.
CLOCK BUTTON (C18)
Press CLOCK button (C18),
ing ▲ or ▼ button adjusts the present time. Holding down either
button above 2 seconds increases or decreases the time by 1 min-
ute every 0.5 second and then by 10 minutes every 0.5 second.
During blinking after setting, press CLOCK button again to confirm
the setting, and then
will be constantly displayed.
Batteries: Remove the cover on the back of the remote control
and insert the batteries with the (+) and (−) poles point-
ing in the proper direction. (Fig. D)
CAUTION
• Use only AAA or IEC R03 1.5V batteries.
• DO NOT use rechargeable batteries.
• All batteries should be replaced at the same time.
• DO NOT dispose of the batteries in a fire as they may explode.
• DO NOT install the batteries with the polarity (+/−) reversed.
• Keep batteries and other things that could be swallowed away
from young children. Contact a doctor immediately if an object
is swallowed.
4. DRAINING EXCESS WATER (Fig. E)
1.
Drain excess water from the chassis by placing a pan under
the drain water outlet. (Fig. E2)
2.
Remove the drain plug, and let the water drain into the pan.
3.
When the water stops draining out, replace the drain plug.
4.
Remove the pan of water.
5.
Operate the unit in Fan mode to dry the interior of the unit.
NOTE:
Remove the drain water from the tank once a week.
Cooling or drying operation, the condensation water will
be drained to the chassis and spattered by water-striking
motor. As the temperature of condenser is high, most of
the condensation water will be evaporated and drained to
outdoor. So usually, only a little condensation water will
be accumulated inside the chassis and you do not need
to discharge the water frequently.
When the chassis is full with water, the buzzer will give
out 8 sounds and "H8" is displayed to remind user to dis-
charge water:

5. CONTINUOUS DRAINAGE

There are 2 ways to remove collected water:
1.
DRAINAGE FROM THE BOTTOM HOLE (Fig. I)
NOTE: When using the continuous drainage option from the bot-
tom hole, install drainage pipe before using, otherwise
poor drainage will affect normal operation of the unit.
Prepare the below accessory.
I1
Drainage hose
I2
Hose band
I3
Screw
I4
Drainage hose clip
I5
Rubber plug
INSTALLATION OF DRAINAGE HOSE CLIP
1.
Remove the rubber cap at drainage port. (Fig. I6)
2.
Fix the drainage hose clip (I4) on the right of rear side plate
near drainage port with a screw (I3). (Fig. I7)
3.
Put the drainage hose (I1) into drainage port and screw it up,
and then bind it with hose band (I2) (Fig. I8)
4.
Put the rubber plug (I5) into the other side of drainage hose, fix
it with hose band (I2) and place it into the drainage hose clip.
(Fig. I9)
For continuous drainage, take the drainage hose from the clip and
pull out the rubber cap on the drainage hose to discharge water.
(Fig. I9)
NOTE:
• After finishing discharging water, put back the rubber cap onto
drainage hose and then fix the hose on the clip.
• After full water protection is eliminated and the compressor has
been stopped for 3 minutes, the unit will resume operation.
2.
DRAINAGE FROM THE MIDDLE HOLE
Prepare the below parts. (Fig. J)
J1 Drainage hose of inner diameter of 14mm (Not included,
available in market)
blinking. Within 5 seconds, press-
J2 Drain connector
1.
To drain, remove the drain cap (J3) by turning it counter
clockwise then remove the rubber stopper (J4) from the
spout. (Fig. J5)
2.
Screw the drain connector (J2) to the spout by turning
clockwise. (Fig. J6)
3.
Insert the drainage hose (J1) into drain connector hori-
zontally below the drainage hole.
Avoid uneven ground and folding the hose. (Fig. J7)
6. INSTALLATION OF POWER SUPPLY CORD
HOOK (Fig. L)
Assemble the power supply cord hook (L1) at the back of the
unit with screws (L2). (Fig L3) The direction of upper hook is
upward. For lower hook, direction is downward.
Wind the power supply cord around the wire hook. (Fig. L4)
7. CLEANING
CLEANING AIR INTAKE GRILLE (Fig. F)
1.
Clean the air intake grille (B10) once every two weeks.
2.
To remove the outside air intake filter (B10) pull the filter off by
pressing the clasp which is on the filter. (Fig. F1)
3.
Remove the dust with a vacuum cleaner.
WARNING
• DO NOT touch the evaporator. It may cause injury or damage.
CLEANING SURFACE
Clean the outside of the unit with a soft damp cloth.
CAUTION
• NEVER use gasoline, solvents, chemical, products or polish as
they could damage the surface.
• Before cleaning the air conditioner, please turn off the unit and
disconnect power. Otherwise, it may cause electric shock.
• DO NOT wash air conditioner with water. Otherwise, it may
cause electric shock.
• Remove the drain water from the chassis and unplug the unit.

8. LONG-TERM STORAGE

At the end of each season, or when you do not plan to use your
unit for an extended period of time, the following procedures are
recommended.
1.
Run the unit 5 or 6 hours with only the "Fan" mode operating
in order to dry the inside.
2.
Remove the drain water from the chassis and unplug the unit.
3.
Clean the unit.
Wipe off any dirt or dust on the unit with a soft damp cloth or
a vacuum cleaner, and then wipe again using a soft dry cloth.
4.
Clean the air intake grille (B10) and replace it.
5.
Store the unit.
The original shipping carton is the best place to store your
unit. If you do not have the original packing materials, cover
the unit with a large plastic bag and store in a cool dry place.
CAUTION
• ALWAYS store the unit in the vertical position.
• DO NOT put heavy objects on top of the unit.
9. TRANSPORTATION
Preferably keep the unit in the vertical position during transportation.
If it is necessary to place the unit in a horizontal position more than
1/2 hour, ALLOW IT TO REMAIN UPRIGHT FOR 24 HOURS
BEFORE OPERATION. Failure to do so may result in damage to the
compressor. Before transporting / moving the unit make sure the
drain tank is empty.
5