7.4 Cleaning of the water inlet valve

The water inlet valve should be cleaned at least once every six months.
The water inlet valve must be cleaned, when it is not or improperly supplied with
water with the tap opened.
1. Close the water tap.
2. Disconnect the appliance from the mains (unplug).
3. Remove the water inlet hose from the tap.
4. Clean the internal filter and reconnect the water inlet hose to the tap.
5. Remove the water inlet hose (A) from the water inlet valve (B / water inlet valve
on the back of the appliance): s. fig. below.
6. Remove the filter (D) from the water valve (B) using a universal pliers (C): s. fig.
below.
7. Clean the filter (D) using some water and a toothbrush (E): s. fig. below.
A
B
C
D
E
8. Reinstall the filter (D) properly.
9. Reconnect the water inlet hose to the appliance again.
Fig. similar: fig. serve as an example only.
W
W
U
~
145
ATER INLET HOSE
ATER INLET VALVE
NIVERSAL PLIERS
F
ILTER
T
OOTHBRUSH
~

Werbung