Herunterladen Inhalt Inhalt Diese Seite drucken

Atag HI21471 Gebrauchsanweisung Seite 123

Induktionskochfeld
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical installation
The following connections are possible.
For appliance types: BI9CA..., BI9CB..., BI9CC... .
NOTE!
Note: The appliance type can be found on the rating plate on the bottom of the appliance.
Voltage between line and neutral conductor must be 220–240 V~. Voltage between lines must be
380–415 V~. Power cord core cross sectional area should be at least as listed in Table for the
following current limiter settings which should be adjusted to your circuit breakers:
Current limiter
settings
3x16A
3x13A
3x10A
3x06A
2x16A
2x13A
2x10A
54
1 phase, 1 neutral conductor (220–240 V~, 50-60 Hz)
To reach the rated maximum power a fuses of 32A is needed.
Install a jumper between terminals 1 and 2 and between terminals 4
and 5.
2 phases, 1 neutral conductor (380–415 V 2N~, 50-60 Hz)
To reach the rated maximum power two fuses of 16A are needed.
Install a jumper between terminals 4 and 5.
(only for NL)
2 phases, 2 neutral conductors (220–240 V 2-2N~, 50-60 Hz)
To reach the rated maximum power two fuses of 16A are needed.
The 2 fases (L1 and L2) should be secured by only one and the same
earth leakage breaker. It is not allowed to run L1/N1 threw a different
earth leakage breaker than L2/N2.
Connection type
3 phases, 1 neutral conductor
3 phases, 1 neutral conductor
3 phases, 1 neutral conductor
3 phases, 1 neutral conductor
2 phases, 1 neutral conductor
2 phases, 1 neutral conductor
2 phases, 1 neutral conductor
Power cord
Number and cross section
type
of Power cord wires
H05V2V2-F
5x1,5 mm²
H05V2V2-F
5x1,5 mm²
H05V2V2-F
5x1,5 mm²
H05V2V2-F
5x1,5 mm²
H05V2V2-F
4x1,5 mm²
H05V2V2-F
4x1,5 mm²
H05V2V2-F
4x1,5 mm²

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis