BSP B/M/V _ _ _ - _ _ _ _ _ - P _ _ S2B - S4(- _ _ _ )
Pressure Transmitters with IO-Link (interface)
With the CE marking we declare that our
products are in conformity with the current EMC
and pressure equipment directive.
Validity
This guide is valid for the following pressure transmitters:
BSP B/M/V _ _ _ - _ _ 009 - P _ _ S2B -...
BSP B/M/V _ _ _ - _ _ 010 - P _ _ S2B -...
IP67,
IP67,
not front flush
front flush
Fig. 1-1: Product illustrations
Intended use
The pressure transmitter was developed for pressure
monitoring of gases or liquids which are compatible with
stainless steel, ceramic and the sealing material
fluoroelastomer (FKM). Depending on the device and
mechanical connection, pressure transmitters are suitable
for various application areas.
The pressure transmitter is installed in a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original Balluff accessories. Use of any other
components will void the warranty.
Modifications to the transmitter or non-approved use are
not permitted and will result in the loss of warranty and
liability claims against the manufacturer.

Downloading further instructions

This guide can also be downloaded from the Internet at
www.balluff.com.
Scope of delivery
Pressure transmitter
Installation guide
4
english
Safety notes
Before commissioning, read the user's guide carefully!
These transmitters must not be used in applications in
which the safety of persons is dependent on the function
of the device (not a safety component acc. to EU
Machinery Directive).
Installation and startup may only be performed by
trained specialists with basic electrical knowledge.
Qualified personnel are persons whose technical
training, knowledge and experience as well as knowledge
of the relevant regulations allows him to assess the work
assigned to him, recognize possible hazards and take
appropriate safety measures.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the measuring system
will not result in hazards to persons or equipment.
IP67 and IP69K,
If defects and unresolvable faults occur in the sensor, take
front flush
it out of service and secure against unauthorized use.
The pressure transmitter must be operated using a power
limited supply (per UL61010) or NEC Class 2 supply.
Always observe the warnings in these instructions and the
measures described to avoid hazards.
Explanation of the warnings
The warnings used here contain various signal words and
are structured as follows:
Type and source of the hazard
Consequences if not complied with
► Measures to avoid hazards
The individual signal words mean:
Identifies a danger that could damage or destroy the
product.
The general warning symbol together with the signal
word CAUTION indicates a danger which can lead to
slight or moderate injury.
The general warning symbol in conjunction with the
signal word DANGER identifies a hazard which, if not
avoided, will certainly result in death or serious injury.
File No.
E227256
SIGNAL WORD
NOTICE
CAUTION
DANGER