Herunterladen Inhalt Inhalt Diese Seite drucken

Downloading Further Instructions - Balluff BTL7-P511-M serie Kurzanleitung

Vorschau ausblenden Andere Handbücher für BTL7-P511-M serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BTL7-P511-M _ _ _ _ -A/B/Y/Z(8)-S32/KA _ _ /FA _ _
Micropulse Transducer - Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The BTL7 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories. Use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.
BTL7...cable
Ø max. 7
BTL7...-S32
13.5
11
2)
Unusable area
3)
Not included in scope of delivery
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A8/B8/Y8/Z8-...
8 mm
1
english
Mounting surface
B: 30-1 mm
Z: 2"-0.04"
2)
Magnet
Thread size
0.5 Ø 25
B: M18×1.5
Z: 3/4"-16UNF
71
25
Mounting surface
G
Thread M4x4/
6 deep
No thread

Downloading further instructions

A complete user's guide can be downloaded from the
Internet at www.balluff.com/downloads-btl7 or
requested via e-mail from service@balluff.de.
Dimensions and function
The BTL7 transducer contains the waveguide which is
protected by an outer stainless steel tube (rod). A magnet
is moved along the waveguide. This magnet is connected
to the system part whose position is to be determined.
In normal operation, the LEDs indicate the operating states
of the transducer:
LED 1
Green
Normal function
Magnet is within the limits.
Error
Red
No magnet or magnet outside the limits.
LED 2
Normal function
Off
Valid Init signal.
Flashing red
Init error
Missing or invalid Init signal and LED 1 is off.
1) Not for BTL7-...-FA_ _
Damping zone
60
Nominal length =
Measuring range
3)
A: 30-1 mm
Y: 2"-0.04"
3)
2)
Thread size
25
71
A: M18x1.5
Y: 3/4"-16UNF
File no. 1)
E227256
2)
LED 1
LED 2
45
46

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis