Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BSP B P S2B-S4 Serie Betriebsanleitung Seite 32

Drucksensoren mit io-link
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BSP B/M/V _ _ _ - _ _ _ _ _ - P _ _ S2B - S4(- _ _ _ )
Pressure Transmitters with IO-Link (interface)
Display and operating elements
1
2 3 4
7
1 Four red LEDs for units selection (bar, mbar, PSI, MPa)
2 LED IO-Link (red): Status indicator for IO-Link
3 LED Out 1 (yellow): Status indicator for Switching Output 1
4 LED Out 2 (green): Status indicator for Switching Output 2
5 Red 7-segment display for measurement value and
parameters
6 Key for menu selection and confirming/entering
7 Key for moving within the menu
Fig. 14-14: Overview of display and operating elements
Status LED
for
IO-Link active (Master-Slave mode)
LED IO-Link
IO-Link inactive (Master-Slave
(red)
off
mode)
Switchpoint 1 reached, switching
for
LED Out 1
output active
(yellow)
off
Switchpoint not reached
Switchpoint 2 reached, switching
for
LED Out 2
output active
(green)
off
Switchpoint not reached
Key functions
Short press
Long press
Short press
Long press
Hold down
both keys
simultaneously
The pressure transmitter is configured according to
VDMA 24574-1.
10
english
5
6
Scroll from Menu 1 to
Menu 5, then return to
display.
Quickly increment
parameter values.
Select menu item within a
menu.
Apply set parameters and
jump to current menu
item.
Jump back to display.
Display messages
Err0...Err3
Error
► Restart device.
If the error is still displayed, the device
must be exchanged. Contact Balluff
Service.
Overload
OL
Value above the measuring range.
Underload
UL
Value below the measuring range. These
error messages are temporary and the
transmitter returns to regular operation in
the normal pressure range.
Nxxx
Firmware Version
Menu operation
Example using menu items 1 to 5:
1. Press
to open Menu 1.
2. Press
to display the values for Switchpoint 1. The
selected value flashes.
3. Press
to select a value. Press
selected value and return to Menu 1.
4. Press
to open the next menu and set the value as
described under 2 and 3.
5. Press
to open Menu 5.
6. Press
to open the first submenu 5/1 and set the
value as described under 2 and 3.
Hold down both keys to exit the menu.
If no key is pressed within 60 sec., the program
returns to the display without saving the
changed value.
to confirm the