  • DEUTSCH, seite 1
BMF 203K-H- _ _ -C-A _ -... / BMF 235K-H- _ _ -C-A _ -...
Magnetic Field Sensors
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
BMF family sensors are designed to detect the position of
pistons in pneumatic and hydraulic cylinders and grippers.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty.
Non-approved use is not permitted and will result in the
loss of warranty and liability claims against the
manufacturer.
General safety notes
Installation and startup may only be performed by
qualified personnel with basic electrical knowledge.
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the measuring system will not result in hazards to
persons or equipment.
If defects and unresolvable faults occur in the measuring
system, take it out of service and secure against
unauthorized use.

Downloading further instructions

A detailed user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
Dimensions and function
The BMF 203/235K-H-_ _-C-A_-... is a magnetic field
sensor and is intended for use in pneumatic cylinders and
grippers having C-slots (BMF 203...) or T-slots (BMF 235...).
BMF 203K-...
Sensor
Control element
yellow LED
orange LED
Active surface
green LED
BMF 235K-...
Active surface
1
english
Connection
cable:
Teach-in button
plug:
M08
M12
Dimensions and function (continued)
LED
Color
State
Green
On
Power OK
Inverse
IO-Link communication active
flashing
Orange On
Switchpoint 2 is active
(magnet is at the taught position)
Off
Switchpoint 2 is inactive
(magnet is not at the taught position)
Yellow
On
Switchpoint 1 is active
(magnet is at the taught position)
Off
Switchpoint 1 is inactive
(magnet is not at the taught position)
Sustained, asynchronous flashing of all LEDs
indicates a serious error. Possible causes are:
Short circuit on an output, sensor overload or
defective sensor.

Electrical connection

BN
M
BK
BMF...-PS-...
WH
BU
BN
M
BK
BMF...-PO-...
WH
BU
BN
M
BK
BMF...-NS-...
WH
BU
BN
M
BK
BMF...-NO-...
WH
BU
BN
BK
BMF...-PI-...
WH
BU
Operating state
+
S1
S2
+
S1
S2
+
S1
S2
+
S1
S2
+
S1 / IO-Link
S2