OUTSIDE REMOVABLE GAS HOB UNITS ▪

INSTALLATION RECESS MINIMUM SIZE

The installation/storage recess must be large enough to house the appliance and its accessories. The
recess must feature a door with a clear width allowing the appliance to slide freely on the metal sliding base
it is supplied with. For the recess and door sizes, refer to the following tables, based on the version of the
appliance in your possession.
model
recess width [mm]
SL1323LC-O
SL1323LL-O
SL1336LC-O
SL1336LL-O
SL1350LC-O
SL1350LL-O
SL1400LC-O
SL1400LL-O
SL1410LC-O
SL1410LL-O
DIAGRAM FOR LC-O VERSIONS
DIAGRAM FOR LL-O VERSIONS
Refer to the drawings in the TECHNICAL DATA SHEETS of each model for further size specifications.
40
recess and door minimum sizes
w
h
[mm]
recess height
450
280
670
280
450
280
670
280
450
280
850
280
450
280
850
280
450
280
850
280
W
D
W
D
SL series
d
[mm]
recess depth
750
560
750
560
950
560
950
560
950
560
A
H
H
a (width) x b (height)
[mm]
minimum size/door clear width
400 x 270
620 x 270
400 x 270
620 x 270
400 x 270
800 x 270
400 x 270
800 x 270
400 x 270
800 x 270
B
A
B

Werbung