2. Remove the blockages from the suction
nozzle, the suction pipe or the suction
hose.
3. Replace the filled dust bag (see chapter
Replace dust bag).
4. Replace the filled safety filter bag (see
chapter Replacing the safety filter bag).
5. Check that the suction head and the dirt
receptacle are correctly seated.
6. Dedust the main filter (see chapter De-
dusting the main filter).
7. Check the seating of the filter and cor-
rect if necessary.
8. Replace the main filter (see chapter Re-
placing the main filter).
Escaping dust when vacuuming
1. Check the seating of the filter and cor-
rect if necessary.
2. Dedust the main filter (see chapter De-
dusting the main filter).
3. Replace the main filter (see chapter Re-
placing the main filter).

Disposal

At the end of its service life, the device is to
be disposed of in accordance with statutory
regulations.

Warranty

The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
32

Technical data

Electrical connection
Mains voltage
Phase
Power frequency
Nominal power
Maximum power
Protection class
Protection class
Maximum permissible
mains grid impedance
Dimensions and weights
Typical operating weight
Length x width x height
Effective main filter area
Effective H-filter area
Ambient conditions
Storage temperature
Device performance data
Container capacity
Vacuum (max.)
Max. volume flow with
suction hose DN50, L=3 m
Max. volume flow with
suction hose DN40, L=3 m
Max. volume flow with
suction hose DN50, L=5 m
Max. volume flow with
suction hose DN40, L=5 m
Suction hose connection
Nominal width of the suc-
tion hose
Main filter order number
Main filter order number
English
V
220-
240
~
1
Hz
50-60
W
2100
W
2300
IPX4
I*
Ω
0.224+
j0.140
kg
42
mm
645 x
655 x
1150
2
m
1.5
2
m
1.6
°C
-10-40
l
40
kPa
19.4
3
m
/h
245
3
m
/h
210
3
m
/h
230
3
m
/h
195
NW
DN70
DN40/
50
9.990-
222.0
9.993-
005.0