Operation

Introduction
This section describes how the different functions are activated and operated.
Additional information on the individual functions can be found in the ""Function de-
scription" section at page 6, or in the "Set points" section in the installation guide.
Power saving
To save power, shut off all lights in the control panel after 2 minutes without operation
(with the exception of the green LED).
Control panel
This is the control panel that comes with each unit. See the descriptions of the buttons
below:
Manual operation
Push this button to activate manual operation.
Fan steps 0-4 can be selected by pressing repeatedly. To stop the unit, the button must
be activated until all four level lamps shut off. An operation shutdown ends after a pe-
riod of four hours, after which the unit will run in manual operation, fan step 3.
Fireplace function
Press and hold for 6 seconds, until fan step 3 blinks on the control panel. The unit will
stop the exhaust function and continue to introduce supply air at fan step 3 for 15
minutes.
Maximum ventila-
The fan runs at level 4 for four hours and is particularly useful for ventilation at high in-
tion
door temperatures, such as when a number of people are gathered at the home. After
four hours, the speed returns to the previously used fan step.
Installer operation
Press Manual
unit will then run at fan step 3 for one hour. All other functions will be overridden dur-
ing this period.
Filter change/
Filter changing and resetting the filter alarm are described in detail in the "Operation"
reset
section on page11.