Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Cleaning; Transport - Scheppach HL810 Original Bedienungsanleitung

Holzspalter
Vorschau ausblenden Andere Handbücher für HL810:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
This prevents the wood from putting pressure on
the holder plates.
• Only split straight cut logs.
• Split the logs in vertical position.
• Never split in horizontal position or across.
• Wear protective gloves when splitting.
Attention! The lateral tray tables may not be used as
splitting support or splitting table.
End of work
• Move the splitting knife to the lower position.
• Release one operating arm.
• Switch the machine off and pull the power plug.
• Close the venting cap.
• Observe the general maintenance instructions.

11. Electrical connection

The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions.
The customer's mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
• The product fulfils the requirements of EN 61000-
3-11 and may only be used at the following con-
nection points: This means that use of the product
at any freely selectable connection points is not
allowed.
• Given unfavourable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
• The product is intended solely for use at connec-
tion points that
a. do not exceed a maximum permissible mains im-
pedance "Z" (Zmax = 0.354 Ω), or
b. have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN".
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
AC motor 230 V~ / 50 Hz
Mains voltage 230 V~ / 50 Hz.
The mains connection and the extension cable have
to be three-core cables = P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-sec-
tion of 1.5 mm². Mains fuse protection is 16 A maxi-
mum.

12. Cleaning

Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.

13. Transport

For transport, the splitting knife A must be complete-
ly moved down. Slightly tilt the log splitter with handle
B on the splitting column until the machine is inclined
on the wheels and can be moved. (Fig 11)
www.scheppach.com
GB | 23

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

5905310901

Inhaltsverzeichnis