12 Technical data
Bewades
Nominal connection width, circuit, input/output
Max. tank volume
Max. flow rate
Max. operating pressure
Min./max. water temperature
Min./max. ambient temperature
Emitter output
UVC power at 254 nm
Emitter service life
Amount of ozone produced, approx.
(at 2.5 l/min air flow, <20% r. h., 25°C)
Expected ozone booster and UV emitter service life
Power supply
Protection class
Power supply capacity
Number of emitters
Operating weight
Production number
Type
RO3UV 25
DN
40
m³
25
m³/h
10
bar
10
°C
5–30
°C
0-40
W
130
W
42
h
9000
g/h
1
h
9000
V/Hz
230/N/PE/50/60
IP54
W
180
n
1
kg
65
PNR
6-180734
EN
RO3UV 50
40
50
10
10
5–30
0-40
200
65
9000
2
9000
230/N/PE/50/60
IP54
270
1
68
6-180715
33