Current measuring
Do not exceed the maximum permitted input values. Do not touch any circuits or
parts of circuits if they may be subject to voltages higher than 25 V ACrms or 35 V
DC! Danger to life!
The maximum permissible voltage in the measuring circuit may not exceed 600 V
in CAT II.
The maximum permissible Measuring >5 A must only be performed for max. 10
seconds and at 10 minute intervals.
Always start current measurements at the highest measurement range and switch
down to lower ranges if necessary. Before changing the measurement range,
always power down the circuit. All current measuring ranges are secured with fuses
and thus protected against overload.
Never measure any currents above 10 A in the 10 A range and no currents above
600 mA in the mA/μA range; otherwise the fuses trigger.
Proceed as follows to measure direct current "DC" (A
1. Switch on the DMM and select "A
range, start with a larger range ("A
Measuring function
A
mA
µA
2. Depending on the measuring function chosen, plug the red measuring lead into the 10A measuring
jack (13) / mAµAºCºF measuring jack (12) and the black measuring lead into the COM measuring
jack (11).
3. Now connect the two test prods in series with the object to be measured (battery, circuit, etc.); the
display indicates the polarity of the measured value together with the currently measured value.
When a minus "-" appears in front of the measured value when measuring direct current, the
current has the opposite direction (or the measuring leads have been swapped).
4. After measuring, remove the measuring leads from the measured object and turn off the DMM.
46
):
", "mA
" or "µA
").
Measuring range
0.001 – 10 A
0.001 – 600 mA
0.01 – 6000 µA
". If you are not sure about the measured
Measuring jacks
COM + 10A
COM + mAµA