The stove does not
turn on automati-
cally
Lock the stove.
Pellets not being
fed into the com-
bustion chamber
The stove runs for
a few minutes and
then turn off
Fume extraction
fan does not stop
18
1. The tank is empty.
2. The resistance does not
reach the temperature
3. Resistance damaged
4. The pellet drops
5. Screw motor defective
6. The grate is not in place
or is dirty
7. Obstruction of nests or
foreign bodies in the chim-
ney or fireplace
8. Check operation of the
glow plug
9. The ash drawer is not
closed properly
10. Clogged flue and chim-
ney
11. Smoke extractor not
working
12. Temperature sensor de-
fective
13. Pellet wet
1. The tank is empty
2. The cochlea is no pellet
3. Technical problem of the
cochlea
4. Reduction motor failure
5. Electronic board faulty
1. Lighting cycle not com-
pleted
2. Temporary failure of elec-
tricity
3. Probes fumes defective or
broken or not inserted
1. The stove has not yet
cooled
1. Fill the tank with pellets
2. Check the electrical wiring and fuses, replace
if the resistance is broken
3. Replace the resistance
4. It is recommended to unplug the power sup-
ply before:
- check that the pellet is not caught in the chute
- check that the cochlea is not blocked by dirt
- check the seal of the pellet-door
5. Contact an authorized service center
6. Check that the hole in the brazier matches
the glow plug, clean brazier
7. Remove any foreign body from the chimney
or flue pipe
8. Make sure that there is power. Replace the
spark plug if burned
9. Close the drawer ashtray
10. Perform periodic cleaning
11. Check the operation of the extractor flue
12. Contact an authorized service center
13. Make sure the place of stowage pellet and
replace it with a handful of dry pellets
1. Load the pellets in the tank.
2. Fill the tank and proceed as instructed be-
fore ignition stove
3. IT IS RECOMMENDED to unplug the power
supply before:
- empty the thank and manually free the au-
ger from obstructions (sawdust)
- release the slide from obstructions
- remove the dust accumulation of pellets in
the bottom of the tank
4. Replace the reduction motor
5. Replace the electronic board
1. Re-run power
2. Re-run power
3. Check and replace sensors
1. Allow the stove to cool. Only after cooling
fan will stop. If the problem persists, con-
tact your authorized service center

Werbung