Cleaning the clearing system
Until a reasonable experience is acquired regarding
the operating conditions, it is advisable to perform
this maintenance on at least a monthly basis.
• remove the electrical feed cable;
• remove the cap from the T-joint and proceed
with the cleaning of the ducts. If necessary, at least
for the first few times, call in qualified personnel;
• carefully clean the smoke discharge system: for
this, contact a professional chimney sweep;
• once a year clean the dust, cobwebs, etc. from
the zone behind the internal covering panels,
paying particular attention to the fans.
14
With a vacuum cleaner
to clean the refractory
material and the walls
of
the
combustion
chamber, in particular
the
front
wall
which are located the
scrapers, (photo 9) the
bottom of the chamber
combusione and the
compartment that is
located below the ash
box. (photo 8)
Also clean the brazier
and the ash box.
After completing the
cleaning, replace the
plate located under the
ash box, the refractory,
its attachment, the ash
drawer and finally the
brazier.
Cleaning the fans
The stove is furnished with fans (environmental
and smoke) positioned at the rear and below the
stove.
in
Eventual deposits of dust or ash on the blades of
the fan can cause an imbalance in the fans leading
to noisy performance. It is, therefore, necessary to
clean the fans at least once a year.
Since said operation requires dismantling several
parts of the stove, have the fans cleaned only by
our Technical Assistance Centre.
Season end cleaning
At the end of the season, when the stove will not
be used for some time, it is advisable to perform a
thorough and general cleaning:
• Remove all the pellets from the container and
the screw feeder;
• Carefully clean the brazier, the brazier support,
the combustion chamber and the ash box.
Once the preceding points have been observed,
it only means that the state of the stove has
been verified. It is necessary to thoroughly clean
the smoke discharge tube or flue and check the
condition of the basket. If necessary, order a new
one from our Authorized Assistance Centre. If
necessary, lubricate the hinges of the door and the
handle. Also check the ceramic fibre cord near the
glass, on the internal wall of the door; if it is worn
or too dry, order a new one from the Authorized
Assistance Centre.