Norms and declarations of conformity
Our company declares that the stove conforms to
the following norms for the EC European Directive
labelling:
• 2014/30 UE (regulation EMCD) and following
amendments;
• 2014/35 UE (Low Voltage Directive) and following
amendments;
• 2011/65 EU (RoHS 2 directive);
• The New Rules of Construction Products (CPR-
Construction Products Regulation) No. 305/2011
regarding the construction world;
• For installations in Italy, please refer to UNI
10683/98 or following changes. For the water-
thermo-sanitary equipment, let the installer give
you the conformity declaration in compliance with
L. 37/2008. While installing the unit respect the
local, national and Europen rules;
• EN 55014-1; EN 55014-2; EN 61000-3-2; EN
61000-3-3; EN 60335-1; EN 60335-2-102; EN
62233, EN 50581.
Safety information
Please carefully read this use and maintenance
manual before installing and operating the stove!
If clarification is needed, please contact the dealer
or the Authorized Assistance Center.
• The pellet stove must only be operated in living
environments. This stove, being controlled by an
electronic board, permits a completely automatic
and controlled combustion; the exchange, in
fact, regulates the lighting phase, 5 power levels
and the shut down stage, guaranteeing the safe
operation of the stove.
• The basket used for combustion allows most of the
ash produced by the combustion of the pellets to
fall into the collection compartment. Nevertheless,
check the basket daily, given that not all pellets
have high quality standards (use only quality
pellets recommended by the manufacturer).
Responsibility
With the delivery of the present manual, we decline
all responsibility, both civil and penal, for accidents
deriving from the partial or total lack of observance
of the instructions contained herein.
We decline every responsibility derived from
improper use of the stove, from incorrect use by
the user, from unauthorized modifications and/or
2
repairs, from the use of replacement parts that are
not original for this model.
The manufacturer declines every civil or penal,
direct or indirect responsibility due to:
• Lack of maintenance;
• Failure to observe the instructions contained in
the manual;
• Use in non-conformity with the safety directives;
• Installation in non-conformity with the norms in
force in the country;
• Installation by unqualified or untrained personnel;
• Modifications and repairs not authorized by the
manufacturer;
• Use of non-original replacement parts;
• Exceptional events.
• Use only wood pellets;
• Keep / store the pellets in a cool
dry place;
• Never pour pellets directly on the hearth;
• The stove must be fueled only with
quality pellets with a diameter of
6 mm and a maximum length of 30
mm of the type recommended by the
manufacturer.
• Before making the electrical connection
of the stove the discharge tubes must
be connected with the flue;
• The protective grill placed inside the
pellet container must never be removed;
• The environment where the stove
is installed must have a sufficient
exchange of air;
• It is forbidden to operate the stove with
the door open or the glass broken;
• Do not use the stove as an incinerator;
the stove should be used only for the
intended purpose;
• Any other use is considered improper
and therefore dangerous. Do not put in
the hopper other than wood pellets;
• When the stove is operating, the
surfaces,
glass,
become very hot: during operation do
not touch these parts without adequate
protection;
• Keep the fuel and other inflammable
materials off the stove.
handle
and
tubes

Werbung