immediately.
To avoid electromagnetic interference the device
should be kept away from televisions and radios.
Always place the portable device on a firm,
horizontal footing.
The unit must always be stored and operated in
an upright position.
The unit must never be covered whilst it is
operating since this prevents air passing in and
out of it, resulting in the unit being damage.
Packaging
The unit is supplied in packaging to prevent it from
being damaged in transit. The raw materials in this
packaging can be reused or recycled.
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety regulations
and instructions may result in an electric shock, fire
and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
2. Layout
Front (Fig. 1)
1. LED display
2. Indicator panel
3. Function button
4. Air outlet grille
5. Trough handles
6. Guide rollers
Rear (Fig. 2)
7. Mains lead hanger
8. Air filter
9. Air inlet
10. Connection operating for exhaust hose
11. Air inlet
12. Connection for continuous condensation drain
Accessories (Fig. 3)
13. Wall adapter
14. Exhaust air hose
15. Foam with connection opening for wall adapter
16. Foam
17. Cover cap for window/wall opening
18. Water drainage hose
19. Activated carbon filter
20. Remote control
16
12.11.2008
15:28 Uhr
Seite 16

3. Proper use

The air-conditioning system is only designed to air-
condition dry rooms with a maximum room volume of
50 m
3
. The room volume depends on the local
conditions. Large window areas, additional heat
sources (PC, television, people, etc.), poor wall
insulation, etc. serve to reduce this room volume.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

Mains voltage:
Refrigerant:
Refrigerant group:
Refrigerant filling capacity:
Cooling capacity*:
Power input*:
Energy efficiency class*:
Area of application: "Room temperature"
Max. pressure:
Max. dehumidifier output (30 °C/80% RH):
Fan speed levels:
Max. air throughput:
Rated current consumption:
Compressor start-up current RLA max.
Sound pressure level:
Housing dimensions H x W x D:
Unit weight:
* Data in accordance with EN 14511

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating
plate are identical to the mains data.
Always place the portable device on a firm,
horizontal footing.
The machine must always be in an upright
position.
220 - 240 V ~ 50 Hz
R410 A
L1
350 g
2020 W
774 W
A (EER 2.61)
18 - 32°C
4.2 MPA
20 l/day
2 + Automatic
260 cbm/h
3.0 A
15 A
≤ 54 dB(A)
710 x 310 x 350 mm
approx. 22 kg