Herunterladen Inhalt Inhalt Diese Seite drucken

System Commissioning And App Setup - EcoFlow Smart Home Panel Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54

7. System Commissioning and App Setup

After you have connected all wires accordingly, clean up all the wires and tie them using a wire
harness. Close the front panel and tighten the screws to secure the door. Label the circuit names
accordingly on the SHP.
1.
Download the EcoFlow app from the App Store, Google Play Store or EcoFlow official site. Set
up the account and sign in.
2.
Connect a DELTA Pro to the SHP without pressing the enable button.
3.
Press the IOT button to enable Bluetooth connection. When the indicator light is flashing, it's
ready to pair with the EcoFlow App.
4.
Open the EcoFlow App and add the device from the "+" icon on the top right. Find the SHP and
click the icon to pair. After Bluetooth connection, you will be asked to choose the Wi-Fi and
enter Wi-Fi password to finish Internet connection.
5.
For first time users, the app will lead through a commissioning process to setup the SHP. Simply
follow the steps to complete the process. Once you have finished the commissioning process on
the app, you are ready to energize the SHP.
6.
After completing the device wiring test, press the enable button (near the infinity port) for the
connected DELTA Pro. The power indicator should turn green. Watch for any abnormal signs
and fault indication.
7.
If there is no sign of fault, turn the main breaker back on and then turn each branch circuit
breaker back on one by one and watch for any fault indication.
a.
If the device wiring testing reports any errors, or if there are any errors, please resolve the issue
following the message shown on the App or contact our customer support from the Help Center
in the App. You can leave your SHP as long as there is no indication of electrical or other type of
sign for a fault. The default mode for SHP is grid power so it will not affect your use of power.
b.
If there is no sign of error, congratulations! You are ready to go!
WARNING
The SHP defaults to grid mode when without power, which means the load is automatically
connected to the grid power if no power is supplied to the SHP or it's started for the first time.
Please make sure energization of load circuits do not endanger any person or incur any property
damage before closing the main breaker.
APP
Control and monitor EcoFlow portable power stations and the SHP remotely with the EcoFlow App.
Download at: https://download.ecoflow.com/app