During installation - Wiring
When using split phase, the Channel 1, 3, 5, 7, 9 AC input should be connected
1
with hot wires on the same phase, the Channel 2, 4, 6, 8, 10 AC input should be
connected with hot wires on another phase.
For split phase operation, the Switching Connector should be removed
2
permanently from the SHP.
When using single phase, each load circuit AC input should be connected to
3
the hot wire.
Install the relay modules in the corresponding places and secure by tightening
the screws. Failure to do so may cause the relay module to come loose, which
4
will produce an error and disconnection of the load channel, as well as risk
overheating and fire.
During installation - Check wiring
1
With a multimeter in continuity setting, confirm that the hot wire in of each
SHP channel is not shorted to neutral.
2
With a multimeter in continuity setting, confirm that the hot wire in of each
SHP channel is not shorted to ground.
Commissioning
1
Make sure the power stations are enabled and that the stop button is off
(raised).
2
Close the upstream breaker of DELTA Pro and energize the DELTA Pro AC
Input channel. The grid indicator (white) will turn on if there is no fault.
3
Turn each branch circuit breaker back on one by one and check the indicator
status of each channel and power indicator. The indicators will stay white.
If you haven't done so already, download the EcoFlow app from Google Play
or the App Store and create an EcoFlow account. Open the app on your
4
mobile device, log into the app and add the Smart Home Panel to your device
pool. For first time users, the app will lead through a commissioning process
to setup the SHP.
5
Update the firmware of the Smart Home Panel to the latest version, then
check whether there are any errors reported on the app.
Follow the instructions in the app to conduct device wiring testing. If the
6
device wiring testing fails, correct the wiring following the prompts in the app
and re-run the wiring test.
7
Turn on the DELTA Pro and update the firmware to the latest version.
8