SERVICING
Regular maintenance is essential for good stove operation.
Before carrying out any maintenance, disconnect the device from the mains power supply.

DAILY CLEANING

Clean with a vacuum cleaner. The whole process only takes a few minutes a day.
USING A VACUUM CLEANER, when the stove is cold
- Open the door, vacuum the hearth, vacuum the space around the combustion chamber where ash falls (there is NO extractable
ash pan).
- Remove the combustion chamber or clean it with a scraper, and unblock any blocked holes on all sides.
- Vacuum clean the combustion chamber compartment, clean touching edges and replace the combustion chamber
- If necessary clean the glass (cold)
NEVER VACUUM CLEAN HOT ASH, since it may damage the vacuum cleaner
After a few months use dry air (PC keyboard type) to clean the flow sensor in the combustion air intake pipe.
EMPTY THE HOPPER AND VACUUM CLEAN THE BOTTOM IF THE STOVE IS NOT IN USE, and in any case every 15
days.
EVERY SEASON
(by the Dealer)
- General internal and external cleaning
- Carefully clean the heat exchange pipes
NEVER loosen the Allen screws inside the firebox: the loader will fall
- Carefully clean and descale the combustion chamber and corresponding compartment
- Clean fan and mechanically inspect the play and fastenings
- Clean smoke duct (replace gasket on the smoke outlet pipe)
- Clean smoke extractor fan compartment, clean flow sensor and check thermocouple
- Clean, inspect and descale ignition heating element compartment and change heating element
- Clean/check display-control panel
- Visually inspect electric cables, connections and power cord
- Clean pellet hopper and check screw feeder-gearmotor assembly play
- Change door seal
- Test screw feeder loading, ignition, operation for ten minutes and shutdown
If the stove is used frequently, it is advisable to clean the smoke duct every 3 months.

OPTIONAL EXTRAS

REMOTE CONTROL (OPTIONAL cod. 633280)
It is possible to buy a remote control to turn the stove on and off and adjust it remotely.
REMOTE IGNITION BY PHONE (OPTIONAL cod. 281900)
The stove may be turned on remotely by phone by having the Dealer connect a dialler to the electronic circuit board (AUX/SE-
RIALE port) via the thin cable optional cod. 620550.