SPINLOCK MOUNTING
The panel thickness may be within a range of 2 to 20 mm.
The drill hole must have a diameter of 86 mm.
Do not drill holes or installation openings in supporting or stabilizing beams!
The mounting location must have sufficient clearance behind the mounting holes or openings.
The required mounting depth is 65 mm.
Drill small holes with the drill, if necessary, enlarge them using a conical cutter, scroll saw, tail
saw or file and finish them. Deburr the edges. It is essential to observe the safety instructions of
the tool manufacturer.
1.
Create a circular hole in the panel considering
the footprint of the device.
2. Remove the spinlock and insert the device
from the front.
3. Orient the spinlock as shown according to the
panel thickness.
4. Feed the cables through the spinlock and
carefully screw it in for at least two turns.
5. Install the connector.