Safety Devices
Safety devices serve to protect the user
and must not be rendered inoperational or
their functions bypassed.
Power switch
The switch prevents unintented starting of
the appliance. Stop the appliance during
breaks or after operation.
Safety catch
The safety catch on the trigger gun pre-
vents the appliance from being switched on
unintentionally.

Commissioning and operation

Definition of abbreviations used:
HP = High pressure
DT = Detergent
Description of the Appliance
When unpacking the product, make sure
that no accessories are missing and that
none of the package contents have been
damaged. If you detect any transport dam-
ages please contact your dealer.
Illustrations on Page 2
1 Carrying handle
2 Coupling element for water connection
3 Connection for water supply with filter
4 ON/OFF switch for appliance
5 Storage, trigger gun
6 DT tank
7 DT metering regulator
8 Transport handle
9 Accessory mount
10 Storage compartment for mains cable
11 Power cable with plug
12 HP hose reel with handle
13 Trigger gun with safety catch
14 HP hose
15 Washing brush
16 Spray lance with pressure regulation
(Vario Power)
12
English
Before Startup
Figures 1-9
Attach the lose individual parts to your
high pressure cleaner.
Figures 10-11
Push out the safety clip in the trigger
gun using e.g. a small screwdriver.
Join HP hose and trigger gun together.
Push clip in until it engages and check
that it is securely fastened by pulling on
the HP hose.
Water supply
According to the applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. Use a
suitable system separator manufactured by
Kärcher; or, as an alternative, a system
separator as per EN 12729 Type BA.
Water supply from mains
For connection values, see type plate/tech-
nical data.
Observe regulations of water supplier.
Use a fibre-reinforced hose (not includ-
ed) with a standard coupling:
- Minimum diameter, 1/2 inches (13 mm)
- Minimum length, 7.5 m.
Screw the coupling unit (supplied) to
the water connection on the appliance.
Push the water supply hose onto the
coupling unit, then connect it to the tap.
Caution
Never operate the high-pressure cleaner
when the tap is turned off as dry running will
damage the HP pump.
If the water supply is not clean, the Kärcher
water filter must be used (special accesso-
ry - order No. 4.730-059).
Drawing in water from open reservoirs
When fitted with the appropriate accesso-
ries, this high-pressure cleaner can draw in
surface water, e.g. from water butts or
ponds (max. suction height 0.5 m).
As the standard coupling system is not
suitable for use in suction mode, the