11. While connecting the radiator to electric installation ensure that the cur-
cuit has a 30 mA residual-current circuit breaker and an appropriate over-
current circuit breaker. With the permanent installation (cable connec-
tion without plug) it is also mandatory to provide an omnipolar cut-off
switch with a minimum contact opening of 3 mm for disconnecting the
device on all poles.
12. The device version labelled PB can be installed in bathrooms in zone 1,
as defined by applicable law, subject to any additional regulations con-
cerning electrical installations in wet areas.
Other versions of the device can be installed in Zone 2 or beyond.
13. The device is recommended for use solely as described in the manual.
14. Ensure that the heater has been installed on a wall in accordance with
its installation manual.
15. Please forward this instruction manual to the end user.