9.2 Installing the wall mounting bracket

Material losses
!
Observe the necessary floor clearance.
KLE 502
KLE 1002
A
mm
210
654
Note
Use appropriate fixing materials.
» Unhook the wall mounting bracket from the
appliance.
» Use the holes in the mounting bracket as a template
for drilling the wall.
» Mark out the holes for the wall mounting bracket.
» Drill the holes and insert rawl plugs.
» Screw the wall mounting bracket to the installation
wall.

9.3 Appliance installation

» Hook the lower slots on the back of the appliance
onto the tabs of the wall mounting bracket.
CLIC
» Tilt the appliance back against the upper tabs.
» Secure the appliance by pushing it towards the wall
until it audibly snaps into place on the wall mounting
bracket.
Installation - for contractors
9.4 Removing the appliance
» To release the appliance, push the metal tabs at the
top of the mounting bracket towards the wall.
9.5 Power supply
WARNING Electrocution
In rooms with high moisture levels, such as shower
rooms and kitchens, install the connection socket
at least 25 cm above the floor.
WARNING Electrocution
Ensure that the power cable is not in contact with
any appliance components.
Material losses
!
Ensure the appliance can be separated from the
power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
Material losses
!
Observe the type plate. The specified voltage must
match the mains voltage.
Note
Ensure that the cross-section of the on-site supply
cable is adequate.
Note
Ensure that a flush-mounted junction box for a per-
manent power supply is installed at a distance of at
least 10 cm from the side of the appliance.
Note
Carry out all electrical connection and installation
work in accordance with relevant regulations.
The appliance is supplied without a plug and has a 3-core
power cable.
» Connect the 3-core power cable to a connection
socket as illustrated:
1
2
3
1 Neutral wire (blue)
2 Live (brown)
3 Control cable (black)

9.5.1 Control cable

Material losses
!
If operating the appliance in programmed mode
using the control cable, observe the correct polarity.
Material losses
!
When not in use, isolate the control cable in order
to prevent a short circuit.
There are 3 possible ways to connect the appliance:
Appliance connected without control cable
The control cable is not connected. The appliance is not
controlled.
» Isolate the control cable.
1
2
3
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kle 502

Inhaltsverzeichnis