6. CONNECTION

1. Start the engine.
2. Plug into AC socket.
3. Economy control switch
When the economy control switch is turned
ON, the economy control unit controls the
engine speed according to the connected load.
The results are better fuel connection and less
noise.

7. SAFETY DEVICES

Output and Overload Indicators
The output indicator light (green) will remain ON during normal operating
conditions. If the generator is overloaded, or if there is a short in the connected
appliance, the output indicator light (green) will go OFF, the overload indicator
light (red) will go ON and current to the connected appliance will be shut off.
Stop the engine if the overload indicator light (red) comes ON and investigate
the overload source.
Before connecting an appliance to the generator, check that it is in good order,
and that its electrical rating does not exceed that of the generator. Then connect
the power cord of the appliance, and start the engine.
When an electric motor is started, both the overload indicator light (red) and
the output indicator light (green) may go on simultaneously. This is normal if
the overload indicator light (red) goes off after about four (4) seconds. If the
overload indicator light (red) stays on, consult your generator dealer.
Oil alert system
The oil alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
falls below a safe limit, the oil alert system will automatically shut down the
engine. The engine only will start again after you have filled new oil.
DC circuit protector
An overload DC circuit will trip the DC circuit protector. If this happens, reduce
the load to the output of the generator and wait a few minutes before pushing in
the circuit protector to resume operation.