Herunterladen Inhalt Inhalt Diese Seite drucken

Ravelli R 1000 Pro Bedienungs- Und Wartungshandbuch Seite 156

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 169
AL
Warning
AL 05 NO IGNITION
AL 06 NO PELLETS
THERMAL
AL 07
ALARM WITH
RESET
AL 08 DEPRESSION
AIR-FLOW
AL 09
METER
AL 11
LOW FLAME
AL 12 FAN RPM
INSUFFICIENT
AL 13
FLOW
AUGER PHASE
AL 14
AUGER TRIAC
AL 15
��
AL 09 - AIR-FLOW METER is an alarm that do not block the operation of the stove. In these conditions, the stove goes into
modulating work, working at fixed extractor revolutions (RDS off). In any case, a periodic visual and acoustic signal indicating
the type of problem remains active. Please contact the local Technical Assistance Centre.
To reset the alarm, keep the OK key pressed for a few seconds. The stove can be restarted manually or automatically (in the case
of an active chronothermostat or external thermostat) only after resetting the alarm.
Use and maintenance manual R 1000 Pro
Reason
The pellet tank is empty.
Setting of pellets and of intake during ignition
phase insufficient.
The resistance for lighting is defective of not in
position
The pellet tank is empty
The ratiomotor does not load pellets.
No pellet loading
The thermostat with manual reset has intervened
The centrifugal fan is defective
Combustion in the fire pot is not optimal
The combustion chamber is dirty
The flue is blocked
The vacuum switch is malfunctioning
The device who read the quantity of inlet air could
be disconnected or defect
The device could be dirty and so not read cor-
rectly
The pellet tank is empty.
Bad setting of pellet and air on ignition in phase
The revolution of smoke fan lowering more the
15% of speed to fan congestion
The door and the ashtray are not correctly closed Check the devices are closed
Bad combustion in the fire pot
Presence of a foreign body inside the air inlet
pipe
The gear motor is not correctly connected
The device in the motherboard who gears the
auger is defect
Solution
Check if there are pellets inside the tank.
Contact local Technical Assistance Centre.
Contact local Technical Assistance Centre.
Check whether there are pellets in the tank
Empty the tank to check that no objects have
fallen inside which could prevent the correct func-
tioning of the auger
Regulate the pellet setting
If the problem continues, contact the area Techni-
cal Assistance Centre.
Reset the thermostat pressing the button on the
back of the stove
Please contact local Technical Assistance Centre.
Switch off the stove, clean the fire pot and regu-
late combustion with the setting of the pellets.
If the problem continues, contact the area Techni-
cal Assistance Centre.
Follow the cleaning operations of the stove as per
the instructions in the booklet
Check that the flue is clear and clean
Please contact local Technical Assistance Centre
Please contact the local Technical Assistance
Centre
Please contact the local Technical Assistance
Centre
Check whether there are pellets in the tank
Contact local Technical Assistance Centre
Contact local Technical Assistance Centre
Switch off the stove, clean the fire pot, the grid
and set the combustion through the set pellet/
flow.
Check for its presence and extract the unwanted
body
Please contact the local Technical Assistance
Centre
Please contact the local Technical Assistance
Centre
Please contact the local Technical Assistance
Centre
EN
Rev.1 29/07/2021
Pag.47

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis