17. Technical data

a) General
Intended use ...................................Indoor use
Voltage supply ................................9 V block battery (6F22, NEDA 1604 or same)
Operating time/battery ....................approx. 35 h (backlight always on, torch off, buzzer off)
Measuring impedance ....................approx. 10 MΩ (200 mV: ≥100 MΩ)
Display range ..................................2000 counts (characters)
Refresh rate ....................................2-3x per sec
Measuring line length .....................each approx. 90 cm
Low battery indicator ......................≤6 V ±0.2 V
Measuring jacks distance ...............19 mm (COM-V)
Auto power off ................................approx. 15 minutes
Data hold ........................................approx. 15 minutes
Measuring category ........................≤ CAT III 600 V
Degree of contamination ................2
Direct voltage ..................................max. 600.0 V / DC
Alternating voltage ..........................max. 600.0 V / AC
Direct current ..................................max. 10.00 A / DC
Resistance ......................................max. 20 MΩ
Operating temperature ...................0 to 40 °C
Storage temperature .......................-10 to +50 °C
Operating/storage humidity ............ 0 ˚C to 30 ˚C: ≤75 % RH (non-condensing)
Operating altitude ...........................max. 2000 m (above sea level)
Dimensions (W x H x D): ................76.5 x 157.5 x 40 mm
Weight ............................................approx. 262 g (without battery)
b) Fuses
F1 Fuse .......................................... ø5 x 20 mm, FF 200mA H 600 V, Breaking capacity: 500 A
F2 Fuse .......................................... ø6 x 32 mm, FF 10A, H 600V,Breaking capacity: 10 KA,
30 ˚C to 40 ˚C: ≤ 50 % RH (non-condensing)
min., Input terminal protection (μA, mA)
Input terminal protection (A)
53

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2446476

Inhaltsverzeichnis