of impact force, test and identify the setting that obtains the best results.
7.2. COMMISSIONING
Commissioning can only be performed after positive results of all testing phases. Partial or "makeshift" commissioning is strictly prohibited.
1_
Prepare the automation technical documentation (to be conserved for at least 10 years), which must contain the following documents: an
overall layout diagram of the automation, electrical wiring diagram, risk assessment and relative solutions adopted, manufacturer's decla-
ration of conformity for all devices used (for TSKY-B use the EC declaration of conformity enclosed) copy of instruction manual for operation
and the automation maintenance schedule.
2_
Permanently affix a label or plate on the door, indicating the operations for manual release and manoeuvres (use the figures in the "User
Guide").
3_
Permanently affix a label or plate on the door with this image (min. height 60mm).
4_
Affix a dataplate on the door, specifying at least the following data: type of automation, name and address of
manufacturer (responsible for commissioning), serial number, year of construction and CE mark.
5_
Compile the automation declaration of conformity and deliver to the owner.
6_
Compile the manual "Instructions and warnings for automation operation" and deliver to the owner.
7_
Produce and supply the owner with the automation maintenance schedule (containing all maintenance
instructions for all automation devices).
8_
Before commissioning the automation, ensure that the owner is adequately informed in writing of all associated risks and hazards (for
example of the manual of instructions and warnings for automation operation).
8. OPERATION
Use of the device for purposes or in circumstances other than as specified in this document is strictly prohibited. Note that this is a mains-pow-
ered automatic device and must therefore be used with caution. The following in particular is recommended:
1_
never touch the device with wet hands;
2_
disconnect the power supply before opening the controls box and/or gearmotor;
3_
never pull the power cable to remove it from the socket;
4_
never touch the motor before ensuring it is completely cool;
5_
only move the door when it is completely visible;
6_
keep away from the operating range of the door when in movement: wait until it is stationary;
7_
never allow children or animals to play in the vicinity of the door;
8_
never allow children or unskilled persons to use the remote control or other activation devices;
9_
perform periodic maintenance;
10_ in the event of a fault, disconnect the power supply and only move the door manually when possible and in safety. Do not intervene on the
door; call an authorised technician for assistance.
11_
never touch any mechanical part during operation;
12_
all actions not expressly envisaged in these instructions are strictly prohibited.

9. MAINTENANCE AND DISPOSAL

This chapter describes the procedures for drawing up a maintenance schedule and disposal of TSKY-B.
9.1_ MAINTENANCE
To maintain a constant level of safety and guarantee maximum lifetime of the entire automation, regular maintenance is required.
Maintenance must be performed in strict observance of all safety instructions in this manual and in compliance with current
legislation and standards.
For devices other than TSKY-B follow the respective maintenance schedules.
1_
For TSKY-B route maintenance is required within maximum six months or 3000 duty cycles from the previous maintenance.
2_
Disconnect all electric power supply sources, including any backup batteries.
3_
Check the condition of all automation materials, with special attention to possible erosion or oxidation of structural parts; replace any parts that
do not guarantee total reliability.
4_
Check the state or wear of all moving parts: belt, carriage, pinions and all door parts; replace any parts if worn.
5_
Reconnect the power supply sources and perform all checks and tests as envisaged in paragraph "6.1 Testing".
9.2_

SPECIAL MAINTENANCE

If more complex operations are required on electro-mechanical parts, the faulty part should be removed to enable repairs in the manufacturer's
workshop by technicians or other authorised centre.
9.3_
DISPOSAl
TSKY-B is made up of different types of material; some may be recycled, such as steel, aluminium, plastic, or electric cables, while others must be
disposed of: batteries and electronic boards.
Some components may contain pollutant substances; do not dispose of into the environment.Seek information on recycling or
disposal systems in observance of current and local standards.
1_
Disconnect the automation and any backup battery from the electrical mains.
2_
Disassemble all devices and accessories, in reverse order of the procedures described in chapter "3 Installation".
3_
Separate where possible all parts which may or must be recycled or disposed of differently, for example metal parts from plastic parts,
electronic boards etc.
4_
Sort and assign the separated materials to specialist waster recovery and disposal centres in your local area.