Herunterladen Inhalt Inhalt Diese Seite drucken

General Safety Requirements - tau TSKY-B Bedienungs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für TSKY-B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 34
1_INSTALLATION WARNINGS -
1)
Carefully read all instructions before installation, as they provide important instructions regarding the safety, installation, operation
and maintenance. Incorrect installation or use of the product may lead to serious physical injury.
2)
Never leave packaging materials (plastic, polystyrene etc.) within the reach of children as they constitute a potential hazard.
3)
Keep the instructions in a safe place for future consultation.
4)
This product has been designed and constructed exclusively for the use specified in this documentation. Any other use not specified herein may
impair product integrity and/or constitute a hazard.
5)
TAU declines all liability for improper use or use other than as specified for this automation.
6)
Never install the product in explosive atmospheres.
7)
The mechanical elements must comply with the requirements as stated in the standards EN 12604 and EN 12605. For non European member
states, in addition to the national reference standards, the above-mentioned standards must be observed to ensure an adequate level of safety.
8)
TAU is not responsible for failure to observe Good Practice in construction of the doors to be power-operated, nor any deformations occurring
during use.
9)
To ensure the maximum safety, in consideration of the hazards that may arise during installation and use of TSKY-B, the installation procedures
must be performed in full compliance with the law, current standards and regulations. This chapter contains general warnings, while other im-
portant warnings are provided in chapters "Preliminary Checks" and "Commissioning".
According to the most recent legislation, the installation of a power-operated door or gate must be in full observance of the
standards envisaged by European Directive 98/37/EC (Machinery Directive) and in particular the standards: EN 12445; EN 12453
and EN 12635, which enable the declaration of presumed conformity.
10)
Before installation, an assessment of the associated risks must be made, including a list of the essential safety requirements as envisaged in Ap-
pendix I of the Machinery Directive, specifying the relative solutions adopted. Note that the risk assessment is one of the documents included in
the automation Technical documentation.
11)
Check whether other devices are needed to complete the automation with TSKY-B on the basis of the specific conditions of use and dangers
present; take into account all risks of impact, crushing, shearing, dragging etc. and other hazards in general.
12)
Installation must comply with all provisions of Standards EN 12453 and EN 12445. In non-EU member states, as well as national reference stand-
ards, the afore-mentioned standards should also be observed to guarantee an adequate level of safety.
13)
Before performing any operations on the system, disconnect from the mains and detach the batteries.
14)
On the automation power line, install a device for disconnection from the power mains with a gap between contacts equal to or greater than 3
mm. Use of a 6A thermal magnetic circuit breaker with multi-pole switch is recommended.
15)
Check upline of the system that there is a residual current circuit breaker with a threshold of 0.03 A.
16)
Ensure that the earthing system is to professional standards and connected to the metal section of the door.
The safety devices (standard EN 12978) enable the protection of danger areas from risks associated with mechanical movements such as
17)
crushing, dragging and shearing.
18)
The use of at least one luminous indicator is recommended for each system, as well as a warning notice fixed suitably to the frame structure, in
addition to the devices specified in point 18.
19)
TAU declines all liability for the safety and efficient operation of the automation in the event of using system components not produced by TAU.
20)
For maintenance, use exclusively original TAU parts.
21)
Never modify components that are part of the automation system.
22)
The automation may only be used after completing the commissioning procedure as specified in chapter 5 "Testing and commissioning".
23)
The installer must provide all information regarding manual operation of the system in the event of an emergency and supply the system User
with the "User Guide" enclosed with the product.
24)
Never allow children or other persons to stay in the vicinity of the product during operation.
25)
Keep all radio controls or other pulse supplier device out of the reach of children to prevent inadvertent activation of the automation.
26)
Transit below the door must occur exclusively when the automation is stationary.
27)
The user must never attempt to repair or intervene directly on the product; always contact qualified personnel for assistance.
28)
Before accessing internal terminals under the TSKY-B cover, disconnect all power circuits. If the disconnect device is not in a visible location, affix
a notice stating: "CAUTION: MAINTENANCE IN PROGRESS".
29)
Maintenance: at least every six months, make a general check of the system, with special reference to the efficiency of the safety devices (includ-
ing, when envisaged, the operator thrust force) and release mechanisms.
30)
All actions not expressly envisaged in these instructions are strictly prohibited.
All documentation related to the system should be kept inside or in the immediate vicinity of the control unit.
2_ PRODUCT DESCRIPTION AND INTENDED USE (fig. 1)
TSKY-B is a range of gearmotors destined for the automation of sectional doors and, by means of the special accessory P-100BANT not supplied,
spring or counterweight up-and-over doors, projecting and non-projecting.
2 solutions of TSKY-B are available: one with a single track sliding guide (L= 3m – moving parts are already assembled at the factory) or in the
3-section version for assembly (moving parts need to be assembled by the installer).
The irreversible system guarantees mechanical blocking of the door when the motor is not operating, and therefore no lock is necessary; an
internal and external manual release (optional) enable door manoeuvres in the event of a power failure or when out of service.
Battery and battery charger accessory P-200T-CHARGE (optional) is also available, which enables certain manoeuvres in the event of a mains
power failure.
The TSKY-B automation has been designed and constructed for indoor use and to control vehicle access. Any other use is strictly
prohibited.
1_ Base
2_ Cover
3_ Door
4_ Control unit
2.1_ APPLICATION LIMITS AND DIMENSIONS (FIG. 2)
All performance data of the products in the TSKY-B range are provided in the table "Technical Data" are the only values that enable and ensure
correct evaluation for use.

GENERAL SAFETY REQUIREMENTS

5_ Courtesy light
6_ Gear unit
7_ Sliding guide
8_ Drive carriage
9_ Door attachment bracket
10_ Front attachment
11_ Chain tensioner
12_ Rear attachment
20
13_Release knob

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tsky1-bK995ma-s

Inhaltsverzeichnis