10. NOISE LEVELS
The noise emission level of the TSKY-B operator, from the work position, is 52 dB(A).

11. MALFUNCTIONS: TROUBLESHOOTING

The automation does not start
a_
Use a Multimeter to check presence of 230 Vac supply voltage.
b_
Check that the NC contacts of the card are effectively normally closed (3 green leds lit) and that the red leds for opening commands are
off.
c_
Set dipswitch 6 (fototest) to OFF;
d_
Set trimmers FRC and FRA to the maximum value;
e_
Use the Multimeter to check that the fuses are intact.
The radio control range is low
a_
Check that the earth connection and aerial signal have not been inverted;
b_
Do not make joints to extend the aerial cable;
c_
Do not install the aerial at low heights or concealed by walls or columns;
d_
Check status of the radio control batteries.
The door opens in the opposite direction
a_
Invert the motor connection (RED and BLACK wires on the motor).
GUARANTEE: GENERAL CONDITIONS
TAU guarantees this product for a period of 24 months from the date of purchase (as proved by the sales document, receipt or invoice).
This guarantee covers the repair or replacement at TAU's expense (ex-works TAU: packing and transport at the customer's expense) of parts that
TAU recognises as being faulty as regards workmanship or materials.
For visits to the customer's facilities, also during the guarantee period, a "Call-out fee" will be charged for travelling expenses and labour costs.
The guarantee does not cover the following cases:
If the fault was caused by an installation that was not performed according to the instructions provided by the company inside the prod-
uct pack.
If original TAU spare parts were not used to install the product.
If the damage was caused by an Act of God, tampering, overvoltage, incorrect power supply, improper repairs, incorrect installation, or
other reasons that do not depend on TAU.
If a specialised maintenance man does not carry out routine maintenance operations according to the instructions provided by the com-
pany inside the product pack.
Wear of components.
The repair or replacement of pieces under guarantee does not extend the guarantee period.
In case of industrial, professional or similar use, this warranty is valid for 12 months.