S5 – Operation: Executing jobs
7.4 Emergency opening of the w ork-
ing chamber door
Crushing hazard and cutting
WARNING
injuries if the working
chamber door is open
If the working chamber door is open during
machining, it will not protect users from bruises and
cuts.
Do not open or close the working chamber door
during machining.
Never operate the machine with the working cham-
ber door open.
Perform the emergency opening only if you are
authorized to do so and if you have received training
on it.
Activate the safety interlock immediately after com-
pleting your work in the working chamber.
Cutting injuries when
CAUTION
touching a rotating tool
If a power failure or a machine malfunction occurs
during machining, the spindle including the inserted
tool keeps rotating. If you touch the rotating tool, you
will suffer from cutting injuries.
Wait until the spindle has stopped rotating before
performing an emergency opening.
The working chamber door is equipped with a safety
interlock that only allows you to open the door when
the machine is powered. You can use the emergency
release of the working chamber door if the working
chamber door is permanently locked.
Location of the opening for the emergency release:
F
. 46 O
IG
PENING FOR THE EMERGENCY RELEASE
You can perform an emergency opening as follows:
1. Switch off the machine at the main power
switch. Disconnect the machine from the eletrical
source.
2. Open the blank magazine door.
3. Deactivate the safety interlock of the working cham-
F
IG
4. Open the working chamber door.
5. Carry out your work in the working chamber.
6. Close the working chamber door.
7. Reactivate the safety interlock of the working cham-
8. Check if the working chamber door actually is
9. If you can still open the working chamber door,
10. Close the opening for the emergency release again
11. Close the blank magazine door.
Original Operating Instructions:  S5
Version: 12/15/2021
ber door, as shown in the figure (
):
below
a. Insert the key for the emergency release of
the working chamber door through the open-
ing.
b. Deactivate the safety interlock of the working
chamber door by turning the key counter-
clockwise by 90°
. 47 U
SING THE KEY FOR THE EMERGENCY RELEASE
Top: Remove the cap
Middle: Insert the key
Bottom: Turn the key
ber door by turning the key for the emergency
release clockwise by 90°.
locked.
repeat the 3 previous steps.
with the protective cap.
EN 41
Fig. 47 see

Werbung