8 Radio-controlled operation (EnOcean)
Type
DS 45 RC radio switch, 4-chan-
nel wall transmitter
Humidity/temperature sensor*
CO2/temperature sensor
VOC/temperature sensor**
PP 45 ACT: 1-channel recessed-
mounted switch
* Not available for PPB 30 units.
** No EnOcean VOC sensor currently available.
If within range, up to 8 radio sensors can be
used with radio-controlled systems.
Radio actuator PP 45 ACT (1 channel): The
PP 45 Act can be used to activate the "Supply
air for exhaust air units" function for PP 45 RC
units. The PP 45 ACT is connected and taught-
in in accordance with the enclosed installation
and operating instructions.
Teaching-in tips
• Radio components are taught-in directly on the
RC-Master (TEACH key).
• Only one slave unit can be assigned to each
master ventilation unit of the same type. Excep-
tion: In systems with PP 45 RC and PPB 30 RC
unit pairs, the additional teaching in of the PPB
30 RC into the master PP 45 is possible.
• Correct operation of a unit pair is monitored by
the master unit.
• Teach-in mode is deactivated each time a radio
component is saved, meaning that it has to be
called up again for each further component.
• If nothing is received within 120 seconds, the
teaching-in process is ended (the LED on the
ventilation unit switches off).
• Teach-in telegrams from non-supported units
are ignored.
56
EEP

8.3 Radio switch

F6-02-01
The DS 45 RC is a double rocker radio switch for
operating PP 45 RC / PPB 30 RC ventilation
units. The operating mode and ventilation level is
A5-04-01
transferred to all taught-in PP 45 RC/PPB 30 RC
A5-09-08
master ventilation units.
A5-09-05
8.4 PP 45 EO EnOcean extension
D2-01-01
module
The PP 45 EO EnOcean extension module allows
radio-controlled PP 45 ventilation units to also be
operated with the wired RLS 45 K control. The
PP 45 EO is connected to the RS 485 interface of
the RLS 45 K.
taught-in with the commissioning software
(RLS 45 K). This activates the teaching mode
and sends a radio telegram. All radio sensors/
radio switches are taught-in directly on the
PP 45 EO. Only the EnOcean module is taught-
in on the master.
→ Commissioning or Commissioning software.
The PP 45 EO EnOcean module can only be

Quicklinks ausblenden: