Herunterladen Inhalt Inhalt Diese Seite drucken

Beninca BISON 35 OTI Bedienungsanleitung Seite 11

Automation für schiebetore
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
INTRODUCTION
Congratulations on your choice of a BISON gear motor.
All items included in Benincà's wide product range stem
from twenty year of our experience in the sector of automatic
systems, always striving to find new materials and advanced
technologies.
For this reason, nowadays we are able to offer you extremely
reliable products that, thanks to their power, efficiency
and long-lasting features, entirely meet the end user's
requirements.
All our products are covered by a guarantee.
Furthermore, an R.C. insurance policy signed with a primary
insurance company, covers any injuries or damages caused
by manufacturing faults.
GENERAL INFORMATION
Automatic system with 400 VAC, three-phase power supply,
for industrial use sliding gates of 3500 kg max weight.
BISON 35 OTI is equipped with:
- anti-crash electronic device (encoder)
- electronic braking.
- three-phase inverter.
SPECIFICATIONS
Mains power supply
Motor power supply
Consumption
Thrust
Operating jogging
Protection level
Operating time
Gate max weight
Rack module
Opening speed
Noise
Lubrication
Weight
PRELIMINARY CHECKS
For a good operation of the automatic system for sliding
gates, the gate/door to be automated shall feature the
following characteristics:
- the guide track and related carriers should be adequately
sized and subject to maintenance (in order to avert
excessive friction during the gate sliding).
- during operation, no excessive oscillations should be
reported to the gate/door.
- the opening and closing stroke should be limited to
a mechanical stop (according to the current safety
regulation).
These preliminary checks are MANDATORY. It is expressly
FORBIDDEN to use the BISON automatic system on doors
and gates not in good conditions or that have not undergone
a correct maintenance.
INSTALLATION
OVERALL DIMENSIONS
Figure 1 shows the overall dimensions of the gear motor,
expressed in mm.
Given the remarkable weight of the actuator, the device
should be handled by at least 2 persons.
Loosen the 4 "A" screws (Fig. 1) and entirely remove the
BISON35 OTI
Three-phase 380/480VAC 50/60Hz
Three-phase 400VAC
3A
3000 N
Intensive use
IP44
-20°C / +50°C
3500 kg
M6 Z 13
reg. 7-19 m/min
<70 dB
BISON OIL (0.3L)
57 kg
front side of the system. Now all elements of the systems
can be accessed.
If only the control unit is to be reached, it is sufficient to
remove the 4 "B" screws by lifting the upper cover.
The niches for the photocell mounting (F) are provided on
the motor removable side.
Accessory plate BISON.P35
(cod. 9623066) NOT INCLUDED
FOUNDATION PLATE - DIMENSIONS
The positioning dimensions of the foundation plate,
expressed in millimeters, are shown in figure 2. The plate
has one single hole for the passage of cable. While laying the
flexible pipe, keep in mind that the hole must be positioned
as indicated in Figure 2 (ref.C).
The plate should be positioned at 13mm from the floor (with
possible adjustment +/- 5mm), 13 mm above floor-level
usually avert any water stagnation.
At this height, the lower edge of the rack tooth should be
at 156 mm.
If the rack is already installed, a fitting base, raised with
respect to the floor, should be required. However, it is not
advisable to lower the fitting surface.
If the rack used is the model RI.M6Z, the edge of the plate
should lie perfectly parallel with respect to the door leaf and
should be positioned at 70 mm. If a different rack is used,
find the correct distance by temporarily fitting it to the door/
gate leaf, then place the gear motor and check that the pinion
and the rack are geared together.
INSTALLATION OF THE FOUNDATION PLATE
Provide for an adequate hole for the foundation.
Prepare the plate by fitting the foundation bolts, as shown in
Fig. 3: Tighten the 4 D1 nuts to the foundation bolt T, then
insert the plate and fix it with washers and the 4 D2 nuts.
Pour cement on the plate (Fig. 4), taking care that the plate
level should lie perfectly flat. Check that the threaded inserts
(I) for the fitting screws are clean and cement free.
Wait that the cement hardens, then remove the D2 nuts and
R washers (Fig. 5), remove the plate, reinsert the D2 nuts and
washers and then replace the plate.
Note: It is also possible to use highly resistant special dowels
to fix the foundation plate onto the floor. In this case, make
sure that there is no water stagnation.
In any case, the foundation plate should be adequate to the
stress exercised on the automatic system.
HOW TO FIT THE GEAR MOTOR
Place the gear motor on the foundation plate, as indicated in
Figure 5, by inserting the cables "I" in the special slots "F".
Introduce the 4 grub screws M12x70 "K" in the four threaded
holes V. The grub screws must lay on the foundation plate.
The gear motor can be lifted from the foundation plate by
using the gains K.
Before locking the grub screws K, by using the washer H and
nuts W, insert the blocking plates Q, as indicated in Figure 5.
The plates Q are ESSENTIAL to ensure the gear motor
stability on the supporting plate.
Fix the gear motor to the base, by using the washers R, the
threaded washers G and nuts D.
The threaded holes allow for the horizontal movement of
the gear motor, which is required to gear/ungear the pinion
to the rack.