IH5828
Output circuit
The encoder's operating voltage must be switched on together with the
downstream electronic unit (e. g., control) to avoid latch-up effects on the
outputs of the encoder.
` Now the encoder can be used.
6 Output circuit
OP, LD5
Fig. 2: Output circuit PP, LD5
LD24
Fig. 3: Output circuit LD24
6.1 Output signals/ Wave form
A
/A
B
/B
0
/0
Fig. 4: Wave form
IH5828 · Date 20.10.2020 · Art. No. 89304 · Mod. status 239/20
5 V
24 V
+UB
A,B,0
/A,/B,/0
GND
+UB
A,B,0
/A,/B,/0
GND
English
19