d) Current temperature in refrigerator
compartment
(first press cooler" button).
e) Temperature selection for
refrigerator compartment
(first press cooler" button).
When selection button 6 is pressed,
the temperature selection is displayed
for five sec. Then the current
temperature in the refrigerator
compartment" is redisplayed.
Note ambient tempera
ture and ventilation
The climatic class can be found on the
rating plate and specifies the ambient
temperatures at which the appliance
may be operated.
Climatic class
SN
N
ST
T

Ventilation

The air at the back of the appliance will
heat up. This warm air must be allowed to
freely escape, otherwise the refrigerating
machine must perform more. This raises
electricity consumption. Hence, the
air inlet and outlet apertures should never
be covered or blocked off!
Permitted ambient
temperature
+10 °C to 32 °C
+16 °C to 32 °C
+18 °C to 38 °C
+18 °C to 43 °C
Connecting the
appliance
After installing the appliance, you should
wait at least ½ hour before switching on
the appliance. While the appliance is
being transported, the oil in the
compressor may leak into the refrigeration
system.
Clean the interior of the appliance before
using for the first time (see Cleaning").
The mains socket should be easily
accessible. Connect the appliance to
a 220-240 V/50 Hz AC mains supply at
a correctly installed socket. The socket
must be equipped with a fuse protection
rated 10 A or higher.
If the appliance is to be operated in a
non European country, check that the
voltage and current type indicated on
the rating plate correspond with the
specifications of your power supply.
The rating plate is situated in the
bottom left hand side of the appliance.
The mains connection cable may be
replaced by an electrician only.
Warning!
!
The appliance may not, under any
circumstances, be connected to
electronic energy saving plugs
(e.g. Ecoboy; Sava Plug) and to power
inverters which convert direct current
to 230 V alternating current (e.g. solar
energy systems, power networks on
ships ).