Herunterladen Inhalt Inhalt Diese Seite drucken

Storage And Disposal; Storage Conditions; Disposal Of Oils And Process Condensate - Comprag RECOM RCW-Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The compressor is overheating.
Excessive starting and stopping
Moisture in discharge air.

7. Storage and disposal

7.1 Storage conditions

the compressor should be kept at a temperature between -20° and +35°С with max.
85% relative humidity.

7.2. Disposal of oils and process condensate.

used oils, greasy filters and separators should be recycled in a sealed container and dis-
posed of at a local recycling or disposal facility. do not allow precipitation to mix with oil.
process condensate contains oil. local environmental regulations govern the degree of
contamination of condensate discharge to sewer. use process Condensate separators to
separate oil and further impurities from the condensate.
replaceable components of a process Condensate separator should be disposed of in the
same way as greasy wiping cloths.
COMPRAG RECOM RCW series
There's insufficient ventilation
in the facility where the com-
pressor is installed.
The oil level is too low.
Cylinder or piston scratched,
worn, or scored.
Compressor check valve leaky,
broken, carbonized or loose.
Fittings not tight enough or
leaking.
Condensation in air tank
caused by
high level of atmospheric
humidity
Increase the air circulation in-
side the facility.
Top up oil.
Repair or replace as required.
Clean or replace as required.
Inspect valves.
Tighten fittings where air can-
not be heard escaping. Check
joints. Do not overtighten.
Drain air tank more often in
humid weather and use an air
line filter.
21

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rcw-3Rcw-11

Inhaltsverzeichnis