Herunterladen Inhalt Inhalt Diese Seite drucken

ESX XENIUM XE6440-DSP V2 Benutzerhandbuch Seite 33

Class d 6-channel amplifier with dsp processor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Malfunction: no subwoofer sound
Reason:
1. The volume of the subwoofer output (channel G / H and SUB OUT) is set too low on the remote control.
Malfunction: „ERROR" message in connection between DSP device and your computer
Reason:
1. The DSP amplifier is in PROTECT mode (protection circuit) or turned off.
Note: The POWER LED and the USB LED must light up blue.
Malfunction: „The COM port could not open..." message in connection between DSP device and your computer
Reason:
1. In the connection window after the software start the wrong COM port has been selected or defined.
The selected port must be between COM1 and COM9.
Malfunction: The stored settings can not be called up on the remote control via mode button
Reason:
1. The settings must be saved numerological (POS1, POS2, POS3, ...)
OPTICAL
REMOTE
INPUT
OPTICAL
TROUBLE SHOOTING
E / F / G / H
HIGH LEVEL
LINE OUT
ON
AUTO TURN ON
PC CONNECT USB
ONLY WITH HIGH LEVEL INPUT
HIGH LEVEL
F+
E+
F -
E -
SPEAKER
BAT T.
INPUT
OUTPUT
+12V
GND
OFF
SPEAKER
BAT T.
INPUT
OUTPUT
+12V
Remedy:
Press the remote controller
and hold. Turn up the volume.
(Refer to page 25).
Remedy:
Remedy the cause
Remedy:
Select the correct port.
Check if necessary the port in the
Device Manager of Windows under
„Ports (COM & LPT)
„USB-Serial CH340".
Remedy:
Save the settings always numerological
(Refer to page 28).
XE4240-DSP
4-CHANNEL AMPLIFIER WITH
DIGITAL SOUND PROCESSOR
REM
AUX
IN/OUT
INPUT
XE6440-DSP
6-CHANNEL AMPLIFIER WITH
DIGITAL SOUND PROCESSOR
V2
PRT.
POW.
V2
33
PRT.
POW.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis