Dmx Mode - EuroLite LED IP PAD Bedienungsanleitung

Cob series
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Dimmer curves (8 types):
Press the MODE button until the display shows DIMMER. Press the ENTER button. You can select the
dimmer CURVE: 01-08 via the UP or DOWN buttons. Confirm your choice by pressing ENTER.
Dimming Curves options:
Linear
LINEAR: the increase in light intensity appear to be linear as DMX value is increased.
SQUARE LAW: light intensity control is finer at low levels and coarser at high levels
INVERSE SQUARE LAW: light intensity control is coarser at low levels and finer at high levels
S-CURVE: light intensity control is fine at low levels and high levels and coarser at medium levels.
The dimmer curves described above are available in two different versions – with the response
characteristics of halogen lamps (dimmer curve 01 – 04) and response characteristics of LEDs (dimmer
curve 05 – 08).

DMX MODE

The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the device will respond to the controller.
Addressing
Press the MODE button until the display shows Add.
As soon as the digits blink, you can select the desired values via the UP or DOWN buttons.
Please press the ENTER button again to confirm and to select a DMX Channel Mode.
Controlling:
After having addressed the device, you may now start operating it via your lighting controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, the display will blink for 3-4 seconds. If there is no data received at the DMX-input, the display
will not blink.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective,
- the cable or connector is defective or the signal wires are not properly connected with the input connector.
Choosing a DMX Channel Mode with 3 or 1 Channel Occupation
After having set the desired addresses and pressed ENTER, you can now choose a DMX Channel Mode.
(3 CH, 1 CH) by pressing the MODE button again. The display shows 3CH.
In case you would rather select the 1-channel mode, press the DOWN button in order to choose the 1CH
setting.
Mode:
Value:
3CH (default setting)
1CH
Press the ENTER button again to confirm and to exit the DMX Mode.