RDM is integrated in the DMX-protocol without influencing the connections. The RDM-data is transmitted via
the standard XLR-poles 1 and 2 – new DMX-cables are not necessary. RDM ready and conventional DMX
devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed
and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
In order to see or to change the RDM PID code if required, press the MODE button and choose FIXTURE
ID.
Press the ENTER button.
Enter the password 050 via the UP or DOWN button.
You can now see or, if necessary, change the individual RDM PID code of the fixture via the UP or DOWN
button.
Please press the ENTER button again to confirm and to exit this mode.
Dimmer speed (step response)
Press the MODE button until the display shows DIMMER.
You can select the dimmer speed: DC1 (response characteristics LEDs) or DC2 (response characteristics of
halogen lamps) via the UP or DOWN button.
Please press the ENTER button to confirm and to exit this mode.

DMX MODE

The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the device will respond to the controller.
Addressing
Press the MODE button until the display shows Add.
As soon as the digits blink, you can select the desired values via the UP or DOWN buttons.
Please press the ENTER button again to confirm and to select a DMX Channel Mode.
Controlling:
After having addressed the device, you may now start operating it via your lighting controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, the display will blink for 3-4 seconds. If there is no data received at the DMX-input, the display
will not blink.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective,
- the cable or connector is defective or the signal wires are not properly connected with the input connector.
29/40
00087754.DOC, Version 1.3