Attention: It is recommended to renew the connection with the power mains after every 8 devices.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
between Signal (–) and Signal (+) in the DMX-output of the last fixture.

Master/Slave Operation

The master/slave operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the device you can find a DMX input plug and a DMX output connector, which can be
used for interconnecting several devices.
Choose the device which is to control the effects. Set the desired Master-mode on the master-device. This
device then works as master-device and controls all other slave-devices, which are to be connected to the
master-device via a balanced microphone lead. Connect the DMX out connectors with the DMX input plug of
the next device.

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.