garbage or a garbage bag.
Regulation and smoke damper:
If one is fixed in the chimney it should not close of more than 80% of the internal diameter of the
chimney.
MALFUNCTIONS
If problems should occur with the use of the stove the cause can possibly be found below. If not,
then you are always welcome to contact your dealer.
The stove is difficult to control – it burns too fast
If the stove is new, then check that the directions have been followed. If the stove is more than 1
year old or if it has been used heavily, then the jointings may need to be changed. If the jointings
sit for too long the heat makes them lose their ability to keep the stove sealed. Check that the
ashpan is closed completely.
If there is heavy draught in the chimney it may be necessary to fit a damper in it.
The stove has poor draught after installation
Check that the mounting instructions have been followed. It is especially the conditions sur-
rounding the chimney that may cause problems. Are diameter and length okay, is it sealed, are
smoke pipe and junctions sealed? Is the cleaning hatch sealed? You may need to contact a chim-
ney sweep to remedy the problem as the chimney may be blocked.
Smoke at soot smell
This can be caused by down-draught in the chimney and most often happens in specific wind
directions. The chimney may be too short for the ridge or trees may have grown and are creating
turbulence.
Remember not to open the door while there are flames.
The stove is difficult to light and may die out
There may be a number of causes. The most typical are:
The damper is not sufficiently open.
The firewood is too wet.
The draught in the chimney is too small or maybe it is blocked or leaking.
The ember layer was too small/incinerated and did not give enough heat to light the logs. Possibly
give some start-up air to the fire by opening the damper (pushed down and to the right) to get
the stove going again. Then the damper has to be closed again (back to position between left and
the middle).
Depending on the problem it may be necessary to contact the dealer, installer or a chimney
sweep.
The glass soots up
The wood is too moist.
Lack of draught in the chimney.
Check that the damper is not closed.
Door is closed too early at lighting (point 3 section 2).

TECHNICAL SPECIFICATIONS

Nominal heat output:
Height:
Width:
Depth:
Weight ca.:
Average values for testing of TT30 models:
Exhaust gas temperature
Exhaust gas mass flow
Efficiency
Nominal Heat output
Flue draught
28
TT30
TT30S
5kW
5kW
1058mm
1058mm
456mm
459mm
367mm
372mm
126kg
160kg
328 °C
4.3 g/s
81,0%
5 kW
12 Pa
TT30G/Classic
5kW
1058/1015mm
456mm
367mm
123/108kg
TT30GS
5kW
1058mm
459mm
372mm
151kg