The chimney must have a minimum internal diameter of Ø150mm.
The chimney must be equipped with an easily accessible cleaning hatch. All joints and connec-
tions must be tight and the chimney must be able to provide a draught of at least 1.2 mm water
gauge (12Pa).
It is possible to connect the wood-burning stove to chimneys that are also used for other purpo-
ses. However, the concrete conditions must be assessed by the fitter and/or chimney sweep.
Demands for the floor:
The foundation must be able to bear the stove and possibly the chimney's weight.

INSTALLATION INSTRUCTIONS IN SMOKE CONTROL AREAS

Installation in a smoke control area requires the additional assembling / installation of the "Dam-
per control unit" which must be installed by the installer. See drawing and picture on page 63
LIGHTING INSTRUCTION

The first time:

The first time the stove is lit is must be done gently as all the materials need to get use to the
heat. The Senotherm varnish that the stove is painted with will harden the first couple of times
the stove is heated, and it may cause some odour nuisances. So make sure that you have proper
ventilation. Do not touch the painted surface, when the stove is hot. The painting has to harden
up first.
Use of the stove:
Below is the procedure used for testing/approval of the stove. It is this procedure that will lead to
the best combustion for the given chimney. Firewood amount and damper setting can be adjusted
to the individual need for heating and the draught in the concrete chimney.
On your new TT30 the work with controlling the air input has been simplified so there is only one
knob/damper (below the door).
Between the left position and the middle position you have the normal area where you control the
air input.
No air input = left position and
maximum air input = middle position.
As help for lighting the control knob/damper can be pushed down a little and pushed completely
to the right. This start help adds some air from below and ensures faster lighting. After a few
minutes the control knob/damper is returned to the normal position (between the left and middle
position).
Lighting and continuous firing at EN-testing
1. The damper/start-up device can be opened (the knob is pushed down and to the right) for a
few minutes at lighting. Put about 10 kindling sticks (dia. 2-3 cm) in the bottom of the stove, laid
in a criss-cross pattern as a log house. Put 2 firelighters in the middle and light them.
2. Leave the door ajar so there is an opening of about 2-3 cm. Leave the stove like that for about
8-10 minutes before you close the door completely. Stay by the stove as long as the door is ajar.
To set the door "ajar" there is a small "door stop mechanism" in the top of the door, which can
easily be turned outwards so as to ensure that the door does not close completely. After 8-10
minutes, open the door and turn the "door stop mechanism" back into place. The door will now
close tightly into the stove. See drawing 4 (page 61)
3. When the fire has burned to embers (no more flames) open the door gently so the ash is not
whirled out through the door. Gently spread out the embers with a poker so they are even.
4. Put 2-3 pieces of firewood in the stove, about 1.7 kg total. The pieces are put in the bottom of
the stove and parallel to the front of the stove with equal distance to the stove's sides and with
mutual distance of about 1 cm. The front piece is best lit if it has a split side that is turned to the
door and one in the embers. Close the door completely immediately.
5. The knob/damper is opened so it is about 2/3 open (between the left and middle position)
and after about 2 minutes the damper is set to about 1/3 open. How much the damper should be
open depends on the individual chimney's draught, but the flames should now stabilise to a calm
fire.
6. When the wood has burned to embers (after about 45-60
minutes) you start again from point 3.