Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data Of The Measuring Accessories; Environmental Note - Benning CM 2 Bedienungsanleitung

True rms digital-multimeter
Vorschau ausblenden Andere Handbücher für CM 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
9.4 Calibration
To maintain the specified precision of the measurement results, the instrument
must be recalibrated at regular intervals by our factory service. We recommend
a recalibration interval of one year. Send the appliance to the following address:
Benning Elektrotechnik & Elektronik GmbH & CO. KG
Service Centre
Robert-Bosch-Str. 20
D - 46397 Bocholt

10. Technical data of the measuring accessories

-
Standard: EN 61010-031,
-
Maximum rated voltage to earth (  ) and measuring category:
With push-on caps: 1000 V CAT III, 600 V CAT IV,
Without push-on caps: 1000 V CAT II,
-
Maximum rated current: 10 A,
-
Protective class II (  ), continuous double or reinforced insulation,
-
Contamination class: 2,
-
Length: 1.4 m, AWG 18,
-
Environmental conditions:
Maximum barometric elevation for making measurements: 2000 m,
Temperatures: 0 °C to + 50 °C, humidity 50 % to 80 %
-
Only use the test leads if in perfect condition and according to this manual,
since the protection provided could otherwise be impaired.
-
Throw the test leads out if the insulation is damaged or if there is a break in
the cable/ plug.
-
Do not touch the bare contact tips of the test leads. Only grab the area
appropriate for hands!
-
Insert the angled terminals in the testing or measuring device.

11. Environmental note

At the end of the product's useful life, please dispose of the device at
collection points provided in your community.
09/ 2013
BENNING CM 2
16

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis