Herunterladen Inhalt Inhalt Diese Seite drucken

Measures For Preparing Welding - Rothenberger ROWELD P 800 B Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für ROWELD P 800 B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

 Set required temperature (cf. temperature controller).
The rise in temperature is indicated by a red signal lamp on the temperature controller.
The display generally indicates the actual temperature value. In accordance with national ordi-
nances and guidelines, e. g. DVS, the heating plate is ready after maintaining the setpoint tem-
perature for at least 10 minutes.
 Check the temperature with a temperature measurement device.
Risk of serious injury! The heating plate can reach temperatures of over 300°C / 572°F!
We highly recommend storing the heating plate in the designated carrying frame
immediately after use!
The welding machine is equipped with a Type 400 digital temperature controller.
The digital temperature controller has been ideally configured and set before leaving our factory.
To set temperature simply press the Fkey until "_SP" is indicated in the display. The opera-
tor can now adjust the setpoint temperature between 0-300°C / 32-572°F with the arrow keys.
If no keys are pressed, the display indicates the actual temperature, the controller automatically
sets the new temperature parameter. As long as the actual temperature is lower than the set-
point temperature, the red arrow flashes (low). If the actual value is larger than the setpoint val-
ue, the red arrow flashes (high). If the actual temperature corresponds with the setpoint temper-
ature, the green bar illuminates. Should the actual surface temperature of the heating plate not
correspond with the actual temperature indicated, it is possible to enter an "offset". To define the
offset, press and hold the F key until "InP" appears in the display (approx. 7 sec.); release
F key, then press the F key as many times as required until "oFS" appears. Correct this
value as required. To save the new settings, press and hold F key until the actual value re-
appears in the display.
Warning! Do not change any other heating plate parameters!
Factory settings:
Menü „CFG"
„S.tu"
0
„h.Pb"
1.0
„h.lt"
0.68
„h.dt"
0.17
„h.P.H"
100
„rst"
0
„P.rE"
0
„SoF"
0
„Lb.t"
0
„Lb.P"
25
„FA.P"
0
Note: The autotuning function could cause the details under "CFG" to deviate minutely. Should
hunting occur, the autotuning function can be activated while the heating plate is cold (set
the menue item "S.tu" to "2" (two) in CFG menue, the system automatically resets the pa-
rameter to "0" (zero).
For lifting the milling equipment and the heating element, use lifting device 53410 or 53323, or a
suitable tool.
3.2.2

Measures for preparing welding

 Pipes smaller than the maximum welding range (diameter) of the machine, mount the
adapter clamping inserts suited for the pipe diameter with the screws found in the accesso-
ries kit.
The set is consisting of six wide-surface shells and two small-surface shells.
Menü „InP"
„Ctr"
8
„tYP"
16
„FLt"
0.1
„FLd"
0.5
„dP.S."
0
„Lo.S"
0
„HI.S"
300
„oFS"
xx
„HI.A"
0
„Lo.L"
0
„HI.L"
280
ENGLISH
Menü „Out"
„AL.n"
0
„r.o.1"
0
„r.o.2"
0
„Ct.1"
20
„Ct.2"
20
„rEL."
0
Menü „PAS"
„Prot"
32
17

Werbung

Inhaltsverzeichnis
loading