2.1.2
Quick installation 35 - 80
Quick installation may only be done if the structure has exactly the same dimensions as the
underside of the module and is sufficiently solid.
1. Position the tube on the underside of the module. Take note that the openings through which the linking pins
go are directly across from each other.
2. Push the linking pins in so that the tube is connected to the module. If the linking pins can't be pushed in
completely (e.g. because they come in contact with the blades), then place them in the half-closed position.
Half-closed
3. Secure the linking pins by screwing in a screw with lock washer from inside the tube into the linking pins.
Drilling
50 and 56 AT(M) in combination with CLICK extension tubes must be secured with 3 extra M4
bolts (M4 bolts spaced 120° from each other) in addition to the 3 standard linking pins.
Install the protective screen
If the AT(M) is installed at heights less than 2.5 m above the floor and/or the AT(M) is within reach
of animals/humans then placement of a protective screen is necessary. Contact with rotating parts
of the AT(M), can cause serious to fatal injuries as result.
Closed