Ethernet Option

The Ethernet option provides a TCP/IP port that can be used to transmit demand templates,
continuous data, for direct access to data via a shared data server, to send email alerts and
terminal status information, and FTP transfer of tare and target tables and complete setup files. It
also provides a connection for backup and restore of the terminal's configuration using the
METTLER TOLEDO InSite
The Ethernet port offers access to the IND570 Webserver via a customer's local network. When
InTouch™ Remote Services are enabled in the IND570, the Ethernet port provides a secure
connection for transmission of terminal status information to the InTouch Enterprise Server.
1.9.3.

COM2/COM3 Serial Ports

Options for additional serial ports include a stand-alone COM2/COM3 option and COM2/COM3
bundled with discrete I/O. Only one option can be used at a time.
COM2 supports an RS-232 connection at communication rates from 300 to 115.2k baud.
COM3 supports an RS-232, RS-422, or RS-485 connection at communication rates from 300 to
115.2k baud.
The serial/discrete I/O combination option includes 2 discrete inputs and 5 discrete outputs. Refer to
section 1.9.1 Discrete I/O,above, for details.
1.9.4.

PLC Interfaces

The IND570 PLC interface options include Analog Output, ControlNet, DeviceNet, EtherNet/IP,
Modbus TCP, PROFIBUS DP, and PROFINET. Only one PLC option can be used at a time.
Additional details about each of these interfaces along with programming guidance can be found in
the IND570 PLC Interface Manual, document #30205335 provided on the documentation CD
included in the terminal packaging. The IND570 PLC Interface Manual along with sample codes
and add-on profiles can also be found at www.mt.com/IND5xx.
1.9.4.1.
Analog Output
Analog Output refers to the representation of an internal system variable using a proportional
electrical signal. Analog Output can be used to transmit a measured value, such as the gross or net
weight.
0-10 volt DC and 4-20 mA signals are provided. Only one signal can be used at a time.
1.9.4.2.
ControlNet
The ControlNet option enables the IND570 terminal to communicate to ControlNet Programmable
Logic Controllers (PLCs) through direct connection to the ControlNet network.
Due to space constraints, the ControlNet interface option can only be used with panel-mount
versions of the IND570 terminals.