Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Cleaning - Scheppach OSM600 Original Bedienungsanleitung

Oszillierender kanten-, band- und spindelschleifer
Vorschau ausblenden Andere Handbücher für OSM600:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
9.3. On/Off switch (3)
• The grinder/sander can be switched on by pressing
the green button „1".
• To switch off the grinder/sander you must press the
red button „0".
m WARNING: Do not reach across the sanding disc to
turn the belt/disc sander ON or OFF. Contact with the
sanding disc can result in serious personal injury.
9.4. Sanding
• Always hold the workpiece firmly during grinding/
sanding.
• Do not exert excessive pressure.
• To prevent the abrasive paper from becoming worn
on one side, the workpiece should be moved to and
from on the grinding/sanding belt or grinding/sand-
ing plate as you grind/sand.
• IMPORTANT! Pieces of wood should always be
sanded with the grain to prevent them splitting. Im-
portant. If the grinding wheel or the grinding/sand-
ing belt becomes jammed during operation, please
remove the workpiece until the tool reaches its top
speed again.
9.5. Bevel sanding (Fig. 15)
The worktable can be tilted from 0° to 45° for bevel
sanding. To tilt the worktable:
• Loosen the fixing screw (4).
• Push the lever (15) down.
• Set worktable to desired angle.
• Retighten the fixing screw (4) again.
9.6. Surface sanding on the sanding belt
• Hold the workpiece firmly, keeping fingers away
from the sanding belt.
• Keep the end pressed firmly against the work sup-
port moving work evenly across the sanding belt.
Note: Use extra caution when sanding very thin
pieces and when sanding extra long pieces, remove
the work support. Apply only enough pressure to al-
low the sanding belt to remove the material.

10. Electrical connection

The installed electric motor is connected and is ready
to work. The connection complies with the relevant
VDE and DIN regulations.
The customer-side mains supply and the used exten-
sion line must meet these regulations.
28 | GB
Defective Electric Connection Lines
Often, insulation damages occur on electrical connec-
tion lines.
Causes are:
• Drag marks if connection lines are led through win-
dow or door clearances.
• Kinks due to improper attachment or routing of the
connection line.
• Cuts caused by running over the connection line.
• Insulation damages caused by pulling the connec-
tion line out of the wall socket.
• Fissures caused by the ageing of the insulation.
Such defective electric connection lines must not be
used and are hazardous due to the insulation damag-
es.
Regularly check the electrical connection lines for
damages. Please make sure that the connection lines
are disconnected from the mains supply during the
check.
Electrical connection lines must comply with the rele-
vant VDE and DIN regulations. Only use connection
lines labelled with H05VV-F. The labelling of the con-
nection cable with the type specification is required.
AC motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate

11. Cleaning

m WARNING! Prior to any adjustment, mainte-
nance or service work disconnect the mains power
plug!
General maintenance measures
Wipe chips and dust off the machine from time to time
using a cloth. In order to extend the service life of the
tool, oil the rotary parts once monthly. Do not oil the
motor.
www.scheppach.com
.
2

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

5903405901

Inhaltsverzeichnis